Assembly and Operating Instructions

Connection as a group controller

Attention
If the control is used as a group control device no bridge can be inserted
between the L and C terminals!
1. Remove the protective caps and check if the encoding switches on the back
side are in the right position.
2. Connect the power supply unit for the UC520 as follows:
Bridge
3. Put the protective caps back on the power supply unit.
4. Fix the power supply unit in the box.
5. Put the operating device in the frame and plug it into the power supply unit.
24
single
central
command
command
Group control
Tubular drive
greenyellow
blue
brown / black
black / brown
Drive controller
single
central
command
command
Central
Connection