Levelling
To ensure correct functioning it is important to level
the appliance. Correct levelling allows for reduction
of vibration generated by the unit in operation.
Thoroughly check the levelling with the use of a
spirit level.
CAUTION!
To ensure proper functioning of the cooling/freezing
appliance, strictly follow the instructions below:
• Do not put the appliance in a place exposed to di-
rect sunlight and near appliances emitting radi-
ation, such as: heat lamps, stoves, radiators etc.
• Avoid integrating or building over of the appliance.
• Do not place any objects on the top of the appli-
ance housing where the refrigerating unit is lo-
cated.
Minimum distance from walls
In order to ensure proper operation of the appli-
ance, during the installation remember to ensure
minimum distance from walls in accordance with
the drawings below. Remember to ensure the ap-
propriate amount of space in front of the appliance
as well - it is necessary for easy opening of the
cooling/freezing chamber doors.
Connection to power supply
The connection to the power source must be made
by trained and qualified service technicians. The
power cable is supplied with the cooling/freezing
Prior to making the connection, make sure:
• The supply voltage corresponds to the appliance
voltage of 230 V / 50 Hz / 1 ph. Proper operation
of the appliance requires that the voltage should
be within ± 6% of the rated voltage.
• The electrical system used to power the appli-
ance must be suitable for rated parameters of
the appliance to be installed.
Connection stages:
• Install the thermomagnetic circuit breaker suit-
able for rated output power of the appliance to
be installed.
• Connect the counter to the output on the thermo-
magnetic circuit breaker.
• Do not place the appliance in a room with relative-
ly high humidity (water can liquify on the housing).
• Do not place the appliance in narrow recesses (if
there is no air circulation, the appliance will not
function properly).
• Do not cover ventilation openings located on the
housing.
• Do not place the appliances back to back (they will
not operate properly).
Ensure that the room where the appliance is placed
is properly ventilated, also outside of working
hours; it is crucial for proper operation of the re-
frigerating unit.
200 - 1500l
FRONT
counter. A thermomagnetic circuit breaker (field
supply) must be installed between the socket and
the power cable of the appliance.
• The electronic system connected to the counter
complies with applicable requirements. Electri-
cal connections and installation of the thermo-
magnetic circuit-breaker have been performed
by a qualified person.
• Make sure the counter is operational (signalled
by an indicator lamp).
EN