Maintenance Table - Airpress H Manuel D'instructions

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Unscrew the fastening bolts on the motor sledge.
Remove the V-belt.
Place the motor at the right distance
from the pump. Make sure that the
pulley of the motor runs in the same
line parallel with the flywheel on the
pump (see drawing). Tighten the
fastening bolts and replace the V-
belt. Worn V-belts should be
replaced by new ones with the same
size.
After +/- 10 operating hours
tighten the head bolts of the V-
belt driven piston compressors according to following table:
Compressor
HL/HK
310-
100
HL/HK
425-
100
HK 425-200
HK 600-200
HK 700-300
HK 1000-500
HK 1000-500
Note: Regular maintenance of your compressor will increase durability and
reliability.
Checking the oil level and refreshing the oil does not apply to the oil free
models HLO 110/6, HLO 200/25, HLO 215/25, HLO 300/50 and HLO 300/100.

MAINTENANCE TABLE

Pump
Bolt
2800/3800
M8
2800/3800
M8
2800/3800
M8
3800
M8
5900/B
M10
6000
M10
7000
M12
(version >01-12-2010)
ATTENTION !
Tightening
moment min.
(Nm)
22,45
22,45
22,45
22,45
45,28
45,25
77,10
28
Tightening
moment max.
(Nm)
27,43
27,43
27,43
27,43
55,34
55,34
94,23

Publicité