Cleaning And Maintenance; Warranty And Repair - Airpress H 215-6 Manuel Utilisateur

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 6
EN
Instruction manual for owner's use
(Translation of the original instructions)
of the pneumatic tool to be used are compatible with the pressure set on the
pressure regulator and with the amount of air supplied by the compressor.
• Always pull out the plug and drain the receiver once you have completed your
work.

4. CLEANING AND MAINTENANCE

WARNING!
Pull the power plug before doing any cleaning and maintenance work on the
appliance.
WARNING!
Wait until the compressor has completely cooled down. Risk of burns!
WARNING!
Always depressurize the tank before carrying out any cleaning and mainte-
nance work.
Never clean the machine and its components with solvents, flammable or toxic
liquids. Us only a damp cloth making sure you have unplugged the compressor
from the current outlet.
After approx. 2 hours of use, the condensate that has formed must be drained
from the receiver. First of all, vent all the air using the accessory connected, as
described above.
The condensation water must be drained off each day by opening the drain valve
(ref. 11 - Fig. 9) (on the bottom of the pressure vessel).
WARNING!
If the water that condenses is not drained, it may corrode the receiver, reducing
its capacity and impairing safety.
As it is a contaminating product, condensate must be DISPOSED of in accordan-
ce with laws on protection of the environment and current legislation.
5. STORAGE
Pull the mains plug out of the socket and ventilate the appliance and all connec-
ted pneumatic tools. Switch off the compressor and make sure that it is secured
in such a way that it cannot be started up again by any unauthorized person.
6. DISPOSAL
The compressor must be disposed in conformity with the methods provided for
by local regulations.

7. WARRANTY AND REPAIR

In the event of defective goods or requirements for spare parts, kindly contact
the sales point where you made your purchase.
8. POSSIBLE FAULTS AND RELATED PERMITTED REMEDIES
FAULT
Reduction of performance.
Excessive performance
Frequent start-up.
request, check for any
Low pressure values.
leaks from the couplings
and/or pipes. Intake filter
may be clogged.
The compressor stops and
Tripping of the thermal
restarts automatically after a
cutout due to overheating of
few minutes.
the motor.
After a few attempts to
Tripping of the thermal cuto-
restart, the compressor
ut due to overheating of the
stops.
motor (removal of the
plug with the compressor
running, low power
voltage).
The compressor does not
Irregular functioning of the
stop and the safety valve is
compressor or breakage of
tripped.
the pressure switch.
Any other type of operation must be carried out by authorized Service Centers,
requesting original parts. Tampering with the machine may impair its safety and
in any case make the warranty null and void.
CAUSE
REMEDY
Replace the seals of the
fitting, clean or replace
the filter.
Clean the air ducts in the
conveyor. Ventilate
the work area.
Activate the on/off switch.
Ventilate the work area. Wait
a few minutes. The compres-
sor will restart independen-
tly. Remove any power cable
extensions.
Remove the plug and contact
the Service Center.
5