Note: Regular maintenance of your compressor will increase durability and
reliability.

MAINTENANCE TABLE

works
draining
condensation water
check
oil level
clean
air filter
refresh oil (first time
after 50 hours)
check V-belt
7.0 POSSIBILIBIES OF FAILURE
1 Compressor does not run at starting pressure:
* blown fuse
* tank at pressure
* motor broken
* defective pressure switch
2 Repeating thermal failure:
* blown fuse
* loose wire
* pressure switch does not releave
air circuit
* too low voltage
* overloading
3 Compressor keeps blowing off air:
* defective non-return valve
4 Too little air production:
* dirty air filter
* V-belt too loose
* defective valves
5 Leaking safety valve:
daily
weekly
- renew the fuse
- discharge
- repair/renew
- repair/renew
- renew fuse
- repair
- repair/renew valve
- remove extension cable or use heavier
- reduce loading
- repair/renew
- clean/renew filter
- tighten V-belt
- renew