24
det mode TIMED
25a/b fill time 30s
or
fill qty 75.0ml
0000138112
SET THE MODE FOR THE DETERGENT PUMP
Once the previous parameter has been confirmed, you will access
this one.
Here you can set the MODE for the DETERGENT PUMP, for both
the first charge and top up.
Press the central button to confirm the shown selection.
By using the left or the right button, you can scroll through the three
available options: TIMED , CYCLIC or QUANTITY.
In TIMED mode, each time the RINSE signals appears on
the S2 input, the DETERGENT PUMP will be activated for
a programmed time. Each time the machine executes a
first charge (either at POWER UP or at S1 or S2LONG),
the pump will dose for a time defined at point 28.
In CYCLIC mode, the DETERGENT PUMP will run
indefinitely with a programmed ON/OFF cycle, for the
duration of the RINSE signal on the S2 input. In the case of
the first charge, it will always be executed for the time set
at point 25
In QUANTITY mode, the DET pump will turn for the time
needed, according to calibration value, to dose the amount
of chemical product set in the point 26c For the first charge,
it will be executed for the time needed to dose the amount
defined at following point 25
Default choice is "TIMED".
Once the chosen option is displayed, press the central button to
confirm it.
This selection will change which is the next parameter to set.
PROGRAMMING THE INITIAL CHARGE
Once the previous parameter has been confirmed, you will access
this one. Here you can set the INITIAL CHARGE, the amount of
detergent you wish to dispense into the machine when it first fills
with water. The parameters define the ACTIVATION TIME of the
DETERGENT PUMP at the power up of the device or at the
st
reception of the 1
charge signal (S1 for 2 Solenoid Valve
machines or S2LONG for 1 SV machines).
If you selected to run the DET PUMP in TIMED or CYCLIC mode at
the point 24, the length of the initial charge can be programmed in
the range from 1sec to 250sec in steps of 1 second. The default is
30sec.
If you selected to drive the DET PUMP in QUANTITY mode at the
point 24, the initial charge can be programmed in millilitres, in the
range from 1ml to 650ml in steps of 1 millilitre. The default is 75ml.
Use the left or right buttons to set the INITIAL CHARGE, then press
the central button to confirm the value.