CHANGING THE POWER ON MESSAGE (HIDDEN MENU)
Once the previous parameter has been confirmed, you will access this
one.
Here you can change the DEFAULT message shown at the power up
of the system.
Keep pressed the central button to confirm the shown message and
pass to the next parameter of the section.
If instead you press quickly central button, you will start to modify the
first character of the message (with right or left key). At this point, you
can change or confirm with the central button all 14 characters of the
string before passing to the next parameter of the section. At any time
you can go on to next parameter by keeping pressed the central
button.
SET THE ACTIVATION MODE OF THE INITIAL CHARGE
Once the previous parameter has been confirmed, you will access this
one.
Here you can define when a dosage for the FIRST CHARGE is to be
performed.
Press the central button to confirm the shown selection.
By using the left or the right button, you can scroll among the two
available options: POWER UP, S1, or S2 LONG
In POWER UP mode, the dosage for the First Charge is
performed each time the WAREDOSE35 is powered up
In SIGNAL 1 mode, the dosage for the First Charge is
performed if a signal is detected on the S1 input.
In SIGNAL 2 LONG mode, the dosage for the First Charge is
performed if a signal is detected on the S2 input for more than
30 seconds.
Default choice is "POWER UP".
Once the chosen option is displayed, press the central button to
confirm it.
This screen will then change to the next parameter in this section.
SELECT THE WORKING MODE
Once the previous parameter has been confirmed, you will have
access to the selection of the working mode of the WareDose35.
By using the left or the right button, you can scroll among the three
available modes:
PROBE standard dosage with a Conductivity Probe
PROBELESS standard dosage without a Conductivity Probe
SIMPLIFIED dosage with a Conductivity Probe
The PROBELESS mode and the SIMPLIFIED mode allow the
selection of the amount of Detergent to dose at the Initial Charge. In
the PROBE mode, at the initial charge, the DET pump will dose to
reach the set point conductivity value in the tank.
Default choice is "PROBE"
Once the chosen mode is shown on the display, just press the central
button to confirm it.