Seko WAREDOSE 35 Manuel D'installation page 16

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

EN
WAREDOSE 35
19
det speed 75%
20
rin mode? TIMED
21a rin speed 50%
0000138112
SET THE SPEED OF THE DETERGENT PUMP
Once the previous parameter has been confirmed, you will access
this one.
Here you set the SPEED OF THE DETERGENT PUMP. This speed
will be applied, in Probe mode, only during the top up of the
detergent (at S3 wash signal). During the first charge, the speed will
always be 100%, in order to reach the set point as soon as possible.
If the fill is set at "POWER UP", the det pump will dose until the set
point is reached. If the fill is set as "S1" or "S2LONG", the det pump
will dose to reach the set point but it will stop if the Signal
disappears.
Press the central button to confirm the shown value.
By using the left or the right button, you can adjust the value from
15% to 100% in steps of 5%.
The default value is 75%.
Once the chosen option is displayed, press the central button to
confirm it.
SET THE MODE OF THE RINSE PUMP
Once the previous parameter has been confirmed, you will access
this one.
Here you can define how you wish to control the RINSE PUMP.
Press the central button to confirm the shown selection.
By using the left or the right button, you can scroll between the four
available options: SPEED, TIMED, CYCLIC or QTY.
In SPEED mode, the RINSE PUMP will run at the selected
speed for the duration of the RINSE signal
In TIMED mode, the RINSE PUMP will run at its maximum
speed for the programmed time once it has detected the
RINSE signal.
In CYCLIC mode, the RINSE PUMP will run indefinitely with
the programmed ON/OFF cycle, for the duration of the
RINSE signal.
In QUANTITY mode, the RINSE pump will turn on for the
time needed, according to calibration value, to dose the
amount of chemical product indicated in point 24.
The default choice is "SPEED".
Once the chosen option is displayed, press the central button to
confirm it. The selected option will change what the next parameter
is.
SET THE SPEED OF THE RINSE PUMP
If you choose to control the RINSE PUMP in SPEED MODE, once
the previous parameter has been confirmed, you will access this
one.
In this mode, the RINSE PUMP will run for as long as there is a
signal voltage present at the S2 input connector.
Press the central button to confirm the shown value.
By using the left or the right button, you can adjust the value from
15% to 100% in steps of 5%.
The default value is 50%.
Once the chosen option is displayed, press the central button to
confirm it.
rev. 1.0