When operating a charger outdoors, always provide
a dry location and use an extension cord suitable
for outdoor use. Use of a cord suitable for outdoor use
reduces the risk of electric shock.
An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The
smaller the gauge number of the wire, the greater the
capacity of the cable, that is, 16 gauge has more capacity
than 18 gauge. An undersized cord will cause a drop in
line voltage resulting in loss of power and overheating.
When using more than one extension to make up the
total length, be sure each individual extension contains at
least the minimum wire size. The following table shows
the correct size to use depending on cord length and
nameplate ampere rating. If in doubt, use the next heavier
gauge. The lower the gauge number, the heavier the cord.
Minimum gauge for Cord sets
Total length of Cord in Feet
Volts
120V
25 (7.6)
240V
50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
Ampere Rating
More
not
American Wire gauge
Than
More
Than
0
6
18
6
10
18
10
12
16
12
16
14

WARNING: If the plug or power cord is damaged,
it must be replaced by the manufacturer or its
representative or by an equally qualified person to
avoid danger.
Do not place any object on top of the charger or
place the charger on a soft surface that might block
the ventilation slots and result in excessive internal
heat. Place the charger in a position away from any heat
source. The charger is ventilated through slots in the top
and the bottom of the housing.
Do not operate the charger with a damaged cord
or plug–have them replaced immediately.
Do not operate the charger if it has received a sharp
blow, been dropped or otherwise damaged in any
way. Take it to an authorized service center.
Do not disassemble the charger; take it to an
authorized service center when service or repair
is required. Incorrect reassembly may result in a risk of
electric shock, electrocution or fire.
Disconnect the charger from the outlet before
attempting any cleaning. This will reduce the risk of
electric shock. Removing the battery pack will not reduce
this risk.
NEVER attempt to connect 2 chargers together.
The charger is designed to operate on standard
120V household electrical power. Do not attempt to
use it on any other voltage. This does not apply to the
vehicular charger.
6
(meters)
50 (15.2) 100 (30.5) 150 (45.7)
16
16
14
16
14
12
16
14
12
12
Not Recommended

WARNING: Shock hazard. Do not allow any liquid to
get inside the charger. Electric shock may result.

WARNING: Burn hazard. Do not submerge the
battery pack in any liquid or allow any liquid to
enter the battery pack. Never attempt to open the
battery pack for any reason. If the plastic housing of
the battery pack breaks or cracks, return to a service
center for recycling.

CAUTION: Burn hazard. To reduce the risk of injury,
charge only D
WALT rechargeable battery packs.
e
Other types of batteries may overheat and burst
resulting in personal injury and property damage.

CAUTION: Under certain conditions,
with the charger plugged into the power supply, the
charger can be shorted by foreign material. Foreign
materials of a conductive nature, such as, but not
limited to, grinding dust, metal chips, steel wool,
aluminum foil or any buildup of metallic particles
should be kept away from the charger cavities. Always
unplug the charger from the power supply when there
is no battery pack in the cavity. Unplug the charger
before attempting to clean.

Charging a Battery

nOTE: To ensure maximum performance and life of lithium-
ion battery packs, charge the battery pack fully before
first use.
1. Plug the charger into an appropriate outlet before
inserting battery pack.
2. Connect the charger and battery pack, making sure
the battery is fully seated. The (charging) light will
blink continuously indicating that the charging process
has started.
3. The completion of charge will be indicated by the light
remaining ON continuously. The battery pack is fully
charged and may be removed and used at this time or
left in the charger.
nOTE: To remove the battery pack, some chargers require
the battery pack release button to be pressed.
Indicators
Charging
Fully Charged
Hot/Cold Pack Delay*
* DCB107, DCB112, DCB113, DCB115, DCB118, DCB132:
The red light will continue to blink, but a yellow indicator
light will be illuminated during this operation. Once the
battery pack has reached an appropriate temperature, the
yellow light will turn off and the charger will resume the
charging procedure.
A charger will not charge a faulty battery pack. The charger
refusing to light could indicate a problem with the charger
or a faulty battery pack.
nOTE: If the charger refuses to light, take the charger and
battery pack to be tested at an authorized service center.