10.2.3. Battery replacement
Work on the electrical system.
Contact with live parts can lead to an electric
shock.
► Batteries may only be changed by specialists.
► Before beginning any work, observe electrical
safety rules.
1. Disconnect the unit.
2. Secure the unit against being switched back on.
Controller battery change:
If error code E11 is displayed (see → Chapter 4.2.1), im-
mediately contact the maintenance service (see → Chapter
10.4).
For reasons of the completeness of data (date, time), an
uninterrupted power supply is required from this installed
battery.
Carrying out a battery change:
Observe separate instructions for changing a battery (safe
removal and replacement). This is available from the
specialists.
Battery type: According to the instructions for changing a
battery.
10.3. What to do if...
The performance and safety of all units is carefully checked
in the AHT test centre.
If a malfunction occurs (also see → Chapter 9.3) or in the
event of the failure of the control and display elements
(see → Chapter 4.3), immediately contact the maintenance
service (see → Chapter 10.4) and tell them the:
-
unit type
serial number of the unit (see → Chapter 2.2.1 /addi-
-
tional stickers on the unit (see → Fig. 9),
-
type of malfunction.
14-digit serial-number
Fig. 9: Sticker with serial number (symbolic representation)
10.4. Maintenance services
If there are questions about maintenance (service,
repair, etc.), please contact your regional, responsible
AHT service partner.
AHT Service line: 00800/73783248
Online contact:
QR Code:
Maintenance services have all the necessary and current
information for the start-up and maintenance such as:
-
spare parts lists
-
circuit diagrams (wiring diagrams)
-
refrigeration wiring diagrams (RI flowcharts)
E_379425_1016
WARNING
www.aht.at/service
11. Disposal
Leaking refrigerant or residues of refrigerant can
cause an explosive gas/air mix. Danger of fire.
► Do not damage the pipework.
► Before disassembly and disposal, professionally
open the refrigerant circuit and extract the refri-
gerant safely and completely. No residues may
remain in the refrigerant circuit.
► Extraction of the refrigerant only by specialists.
Improper disposal. Environmental damage.
► Pay particular attention to safe and environmen-
tally sound disposal
- of the refrigerant
- the insulating foam (polyurethane foam thermal
insulation with pentane)
- the compressor oil
- the battery.
► Units: Separate collection of electrical and elec-
tronic equipment in accordance with the valid
national disposal regulations (e.g. WEEE inside
the EU) and the regulations of the local disposal
partner.
► Batteries should be disposed of properly in
accordance with the valid national disposal
regulations.
► Units and batteries may not be disposed of with
normal domestic waste.