Technical Data; Actuator General - Eaton CROUSE-HINDS Série Mode D'emploi

Masquer les pouces Voir aussi pour CROUSE-HINDS Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Actuator 1 x 4 pole
S 2
S 4
S 3
S 1
S2 S3
S4
S1
12
22
34
R1
11
21
33
14
24
34
R2
13
23
33
22
32
12
R3
11
21
31
12
24
34
R4
11
23
33
12
22
32
R5
11
21
31
Actuator 2 x 2 pole
S 2
S 4
S 3
S 1
S2
S3
S1
12
22
R1
11
21
14
24
R2
13
23
12
22
R3
11
21
12
24
R4
11
23
12
22
R5
11
21
12
Explosion protected built-in components
GHG 4. and GHG 2
1

Technical Data

1.1

Actuator general

ATEX type examination certificate:
Marking acc. to 94/9/EG and standard:
IECEx type examination certificate:
Category of application:
44
43
Operating temperature:
44
43
Perm.ambient temperature in original packing:
42
1.1.1 Actuator 2 pole for
41
push button, Mushroom head p.b., switch and Key-operated pushbutton
44
1.1.2 Actuator 4 pole for
push button, Mushroom head p.b., switch and Key-operated pushbutton
43
44
Rated voltage:
Rated current
43
14 A
16 A
12 A
15 A
Switching capacity acc. to
AC 15
Switching capacity acc. to
DC 13
with gold-tipped contacts:
Supply terminal:
S4
34
44
Prüfdrehmoment Anschlussklemmen
33
43
Weight:
34
44
33
43
32
42
31
41
34
44
33
43
32
44
31
43
IBExU14ATEX1030U
EN 60079-0
D II 2 G Ex d e IIC/IIB Gb
D I M 2 Ex d e I Mb
IECEx IBE 14.0005U
IEC60079-0
Ex d e IIC/IIB Gb
Ex d e I Mb
-45 °C
to
II 2 G ... IIC
-60 °C
to
II 2 G ... IIB
-60 °C
to
up to 500 V
Rated supply
Permissible ambient
terminal
temperature max.
2.5 mm²
40 °C
4.0 mm² single wire 40 °C
2.5 mm²
50 °C
4.0 mm² single wire 50 °C
(EN 60947-5-1):
250 V / 6 A
(EN 60947-5-1):
24 V /
6 A
max. 400 mA
2 x 1.0 - 2.5 mm²
1 x 4.0 mm² singel wire
2.5 Nm
2 pole
approx 0.15 kg
4 pole
approx 0.35 kg
GB
+80 °C
+80 °C
+80 °C
500 V / 4,0 A
60 V /
0,8 A
110 V / 0,5 A

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ghg 410Ghg 249

Table des Matières