14
Explosion protected built-in components
GHG 4. and GHG 2
1.1.6 Diode
1.2

Terminal block

ATEX certificate:
Marking acc. to 94/9/EC and standard:
EN 60079-0
IECEx certificate:
Category of application:
IEC60079-0
Type of terminal:
Rated voltage:
Conductor cross-section:
Test torques:
Weight:
1.3

Signallamp

ATEX type examination certificate:
Marking acc. to 94/9/EG and standard:
IECEX type examination certificate:
Category of application:
Appliation temperature
(Other temperatures possible with special versions)
Perm.ambient temperature in original packing:
Rated voltage /Rated current:
"e" increased safety
"i" intrinsically safe version
"e" increased safety
Ex-i Datas:
U i
I i
Ci
Li
Pi
Supply terminal:
Test torques:
Weight:
SEV 13 ATEX 0178 U
II 2 G Ex e II
IECEx SEV 13.0012 U
Ex e II
6 x MUT 4
up to 352 V
2 x 0.2 - 4.0 mm²
0.6 - 0.8 Nm
approx. 0.08 kg
IBExU 12ATEX 1047 U
EN 60079-0
D II 2 G Ex de IIC/IIB Gb
D II 2 G Ex d ia IIC/IIB Gb
IECEx IBE 13.0031U
IEC60079-0
Ex d e IIC/IIB Gb
Ex d ia IIC/IIB Gb
D II 2 G Ex ... IIC
-45 °C up to +60 °C
D II 2 G Ex ... IIB
-60 °C up to +60 °C
-60 °C up to +60 °C
20 V
up to 254 V AC/DC 4 bis 15 mA
10 V
up to 30 V
12 V
up to 24 V
30 V
100 mA
0
0
750 mW
2 x 1.0 - 2.5 mm²; 1 x 4.0 mm² starr
2.5 Nm
ca. 0.15 kg
GB
DC
max. 25 mA
AC/DC max. 24 mA