Operation; After Initially Putting Into Operation And Following Long Periods Of Disuse; Putting Out Of Operation; Maintenance And Cleaning - Abicor Binzel CR1000 Mode D'emploi

Masquer les pouces Voir aussi pour CR1000:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

CR1000/CR1250

7 Operation

NOTICE
• The cooling unit may only be operated by qualified personnel (in Germany see TRBS 1203).
• Please also consult the operating instructions for the welding components and welding torch.

7.1 After initially putting into operation and following long periods of disuse

1 Check the tightness of the coolant connections.
2 In case of leakages, tighten the hose clip at leak points using pliers or retighten screw terminals using a
screwdriver.

8 Putting out of operation

NOTICE
• When putting the system out of operation, ensure that the procedures for switching off all the welding
1 Disconnect the mains plug on the cooling unit.

9 Maintenance and cleaning

Under normal operating conditions, the cooling unit does not require maintenance.
Despite the above, scheduled maintenance and cleaning are prerequisites for a long service life and a fault-
free operation.
Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout the entire duration of maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Switch off the entire welding system.
• Disconnect the mains plug at the robot welding power source.
Electric shock
Dangerous voltage due to defective cables.
• Check all live cables and connections for proper installation and damage.
• Replace any damaged, deformed or worn parts.
NOTICE
• Maintenance and cleaning work may only be carried out by qualified personnel (in Germany see
• Always wear your personal protective equipment when performing maintenance and cleaning work.
system components are observed.
DANGER
DANGER
TRBS 1203).