Fault
Cause
Water flow too low
• No cooling liquid in the tank
or non-existent
• Coolant level too low
• Blockage or foreign object in the cooling circuit
• Coolant pump fuse defective
• Coolant pump defective
• Cooling circuit interrupted
• Air in the cooling circuit
Cooling capacity too
• Fan defective
low
• Coolant pump defective
• Cooling unit dirty
• Cooling unit with too low cooling capacity
connected
High running noise
• Coolant level too low
level
• Coolant pump defective
Leakage
• Connectors loose
• Hoses kinked
• Coolant pump defective
• Cooling liquid temperature too high
Troubleshooting
Tab. 9

11 Disassembly

Risk of injury due to unexpected start-up
The following instructions must be adhered to throughout the entire duration of maintenance, servicing,
assembly, disassembly and repair work:
• Switch off the power source.
• Disconnect the mains plug.
NOTICE
• Disassembly may only be carried out by qualified personnel (in Germany see TRBS 1203).
• Please also consult the operating instructions for the welding components and welding torch.
• Observe the information provided in the following section:
 8 Putting out of operation on page EN-17.
DANGER
Troubleshooting
• Fill cooling liquid
• Top up cooling liquid
• Check coolant hoses and connections
• Rinse cooling circuit
• Replace fuse
 6.3 Before initially putting into operation on
page EN-15
• Replace the defective component
• Check the cooling circuit connections
• Check coolant hoses for damage
• Bleed
 6.3.1 Bleeding the system on page EN-16
• Replace the defective component
• Contact the service team
• Replace the defective component
• Contact the service team
• Blow dry compressed air through the cooling unit
• Use a cooling unit with a higher cooling capacity
• Top up cooling liquid
• Replace the defective component
• Check for dirt
• Retighten clamp points
• Check hose guides, correct if necessary
• Replace hoses
• Replace the defective component
• Contact the service team
• Clean the cooling unit
• Check the fan is functioning correctly