Putting Into Operation - Abicor Binzel ADF 600S Mode D'emploi

Casque de soudage automatique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 56
ADF 600S

6 Putting into operation

The ADF 600S must be adapted to the respective user prior to the first use. Use only an ADF 600S that is
adjusted precisely to your head size.
6.1 Removing protective film / replacing viewing pane
1
6
1
Retaining frame
2
Outside viewing pane
Fig. 3
Removing protective film / replacing viewing pane
1 Remove the retaining frame (1) incl. viewing pane (2). Push the viewing pane (2) out of the retaining
frame (1) and remove the film or replace the viewing pane (2) with a new one.
NOTICE
• Leave the control cable installed (3) when removing the automatic filter (6) on the ADF 600S (5).
2 Remove the automatic filter (6) by pushing the fastener clips upward and downward. Remove the film or
replace the viewing pane (4) with a new one.
3 Insert the automatic filter (6) back into the ADF 600S (5).
4 Insert the viewing pane (2) in the retaining frame (1).
5 Click the retaining frame (1) incl. viewing pane with four points in the ADF 600S (5).
All manuals and user guides at all-guides.com
3
Control cable
4
Inside viewing pane
6 Putting into operation
2
3
4
5
5
ADF 600S
6
Automatic filter
EN - 9

Publicité

Table des Matières
loading

Table des Matières