7. SPECIFICATIONS
Table 1 Line Mode Specifications
MODEL
Input Voltage Waveform
Nominal Input Voltage
Low Loss Voltage
Low Loss Return Voltage
High Loss Voltage
High Loss Return Voltage
Max AC Input Voltage
Nominal Input Frequency
Low Loss Frequency
Low Loss Return Frequency
High Loss Frequency
High Loss Return Frequency
Output Short Circuit Protection
Efficiency (Line Mode)
Transfer Time
Output power derating:
When AC input voltage drops to 170V,
the output power will be derated.
INFOSEC UPS SYSTEM - 15, rue du Moulin - 44880 Sautron - FRANCE - www.infosec-ups.com Hot Line –
Tel + 33 (0)2 40 76 15 82 - Fax + 33 (0)2 40 94 29 51 - hotline@infosec.fr – 10 24 AA 59 203 08
WATTSON Moov 1200
Sinusoidal (utility or generator)
170 Vac ± 7V (UPS);
90 Vac ± 7V (Appliances)
180 Vac ± 7V (UPS);
100 Vac ± 7V (Appliances)
50 Hz / 60 Hz (Auto detection)
Circuit Breaker
>95% ( Rated R load, battery full charged )
10ms typical (UPS);
20ms typical (Appliances)
Output Power
Rated Power
50% Power
90V
WATTSON Moov 2500
230 Vac
280Vac ± 7V
270Vac ± 7V
300 Vac
40 ± 1Hz
42 ± 1Hz
65 ± 1Hz
63 ± 1Hz
170V
280V
Input Voltage
59