Télécharger Imprimer la page

CAME ZM3E Manuel D'installation page 52

Publicité

Thrust
Before every opening or closing manoeuvre, the leaves thrust inwards to release the electric lock.
The thrust time is set with the [Thrust T.] function
[FUNCTIONS]
Total stop
This stops the gate and excludes automatic closing. Use a control device to resume movement.
[FUNCTIONS]
CX input
Associate a function with the CX input.
[FUNCTIONS]
CY input
Associate a function with the CY input.
[FUNCTIONS]
CZ input
Associate a function with the CZ input.
[FUNCTIONS]
[Thrust]
[Total stop]
[CX input]
[CY input]
[CZ input]
[Deactivated] (Default)
[Close]
[Open]
[Open-Close]
[Deactivated]
[Activated] (Default)
[Deactivated]
[C1] = Reopen while closing (Photocells) (Default)
[C2] = Reclose while opening (Photocells)
[C3] = Partial stop Only with [Automatic close] activated.
[C4] = Obstacle standby (Photocells)
[C7] = Reopen while closing (sensitive edges)
[C8] = Reclose while opening (sensitive edges)
[Deactivated]
[C1] = Reopen while closing (photocells)
[C2] = Reclose while opening (Photocells)
[C3] = Partial stop (Default) Only with [Automatic close]
activated.
[C4] = Obstacle standby (Photocells)
[C7] = Reopen while closing (sensitive edges)
[C8] = Reclose while opening (sensitive edges)
[Deactivated] (Default)
[C1] = Reopen while closing (photocells)
[C2] = Reclose while opening (Photocells)
[C3] = Partial stop Only with [Automatic close] activated.
[C4] = Obstacle standby (Photocells)
[C7] = Reopen while closing (sensitive edges)
[C8] = Reclose while opening (sensitive edges)

Publicité

loading

Ce manuel est également adapté pour:

Zm3ecZm3ep