[LANGUAGE]
Automatic closure
Activate automatic closing.
[FUNCTIONS]
Hold-to-run
With the function active, the operator opening movement (command 2-3) or closing movement (command 2-4) is interrupted
when the control device is released.
When the function is active, it excludes all other control devices.
[FUNCTIONS]
Detecting obstacles
With the function active, the gate remains idle if the safety devices detect an obstacle. The function is active when the gate is
closed, open or after a complete stop.
[FUNCTIONS]
Safety devices test
Check that the photocells connected to the inputs are operating correctly, after each opening and closing command.
[FUNCTIONS]
Pre-fl ashing
The fl ashing beacon is activated before each manoeuvre.
The pre-fl ashing duration is set with the [Pre-fl ashing T.] function
[FUNCTIONS]
[Automatic close]
[Hold-to-run]
[Obstruction det.]
[Safety devices test]
[Pre-fl ashing]
[Italiano] (Default)
[English]
[Français]
[Deutsch]
[Español]
[Português euro]
[Português bras]
[Deactivated]
[Activated] (Default)
[Deactivated] (Default)
[Activated]
[Closing]
[Deactivated] (Default)
[Activated]
[Deactivated] (Default)
[CX]
[CY]
[CZ]
[CX+CY]
[CX+CZ]
[CY+CZ]
[CX+CY+CZ]
[Deactivated] (Default)
[Activated]