AS-I DESIGN
9.1
Connection options
Connection left:
1 x M16 x 1.5 cable gland with multipole connection (M12 plug
according to IEC 61076-2-101, 4-pole) to an 8 cm or 80 cm
long cable
Connection right:
1 x M16 x 1.5 cable gland for external initiator
9.2
Number of connectable control
heads
In AS interface versions with extended addressing range (A/B slave),
1 master can communicate with 62 slaves.
In AS interface versions with addressing range 31 slaves, a maximum
of 31 control heads can be connected to a bus line (the address range
restriction).
9.3
Bus line length
The bus cable may be a maximum of 100 m long. When designing the
system, consider the length of the round cable leading directly to the
control head (see example calculation in the operating instructions).
16
english
Type 8681
AS-Idesign
9.4
Electrical data
Power supply of the solenoid valves (SVs):
Setting the power supply of the solenoid valves using jumpers on
the AS interface electronic module.
Standard: Via AS-i
29.5 ... 31.6 V DC according to specification;
21.0 ... 31.6 V DC according to specification
Power24
Input/Proximity switch (external initiator: S4 in):
Power supply:
Current carrying capacity
Sensor supply:
Design:
Inputs:
(from master perspective) 1 x external initiator
Outputs (from master perspective) / Solenoid valve:
Typ. switching capacity
Typ. continuous output
Option: External
(19.2 V DC to
31.6 V DC)
Applied AS-i voltage at the
control head - 10%
Max. 30 mA; short-circuit protection
DC 2 and 3 wire, NO or NC;
PNP output
3 binary feedback signals and
0.9 W (per solenoid valve, for 200 ms
after switching on)
0.6 W (per solenoid valve, from 200 ms
after switching on)