onto the spigot (nominal width DN 160) of the outlet side so that
the exhaust air outlet of the air circuit bend is as far away from
the unit's intake opening as possible. Also observe the minimum
clearances as shown in the illustration. The hot-water heat pump
air connection stubs ("intake stub" and "outlet stub") are labelled
with stickers.
*
Minimum clearance between the exhaust air outlet in the air circuit bend and
the wall is 1.2 m
Minimum room height for "free venting" is approx. 2.5 m

4.2 Set-Up

Remove the three M12 transport restraint screws fixing the
unit to the pallet.
Remove pallet and install the three M12 supporting feet (in
plastic bag attached to the cylinder barrel nipple).
Position the hot-water heat pump and align vertically by ad-
justing the device feet! Then tighten the counternuts on the
device feet.
www.dimplex.de
5

Installation

5.1 Connecting the Water Pipes

The water connections (see Cap. 1 on page II ) are at the rear of
the unit.
Important information:
Circulation pipe
For energy efficiency reasons, the circulation pipe circuit type
should not be used. When installing a circulation pipe in the hot
water distribution system, provide a valve or a similar device as
shut-off facility. Circulation is enabled according to use (time or
requirement control).
NOTE
Hot water, cold water and circulation connections:
These pipe nipples contain plastic inserts which serve to protect against
corrosion (in particular to the pipe nipple flange surfaces). These plastic
inserts remain in their positions after the water pipes have been installed.
ATTENTION!
When installing the on-site pipework, ensure the pipes do not get
contaminated (flush pipes before connecting hot-water heat pump)!
5.2 Connecting the Condensed
Water Pipe
The condensed water hose is fed through the foil cladding at the
rear of the device. It should be routed so that the condensate
produced (during heat pump operation) can flow away freely.
There is a pressureless seal valve which must also be relocated
when shortening the condensed water hose (valve can be easily
removed and replaced into the hose). This valve is of special im-
portance if longer air hoses are fitted to the device or if a filter is
installed on the exhaust air side. The condensate should be
drained into a siphon (see maintenance information 7.1).
5.2
EN-5