Filling the system

When starting up the system, make sure that the hydraulic
unit lockshield is open. If there is no electric power and the
2.9
Evacuating air while filling the system
-
Open all the system interception devices (manual or
automatic);
-
Start the filling by slowly opening the system water
filling tap;
-
For units installed in a vertical position using a screw
driver vent any air from the battery through the breather
valve.
A
Venting of the battery
2.10

Electrical connections

Make electrical connections according to the requirements
set out in sections General Warnings and Fundamental
safety rules, and by reference to the diagrams present in
the Chapter referring to the mounting, and connecting of
the on board control panel.
Before doing any work, make sure the power is switched
2.11

Maintenance

Routine maintenance is indispensable to keep the Aquarea
Air cooler-convector in perfect working condition, safe
and reliable over the years. This can be done every six
2.12

Cleaning the outside

Before every cleaning and maintenance inspection,
disconnect the appliance from the mains by switching
off the master switch.
Wait until the parts have cooled down to avoid the risk
of burns.
thermo-valve has already been powered use the special
cap to press the valve stopper to open it.
-
When water starts coming out of the breather valve
close these and continue filling the system.
Check the hydraulic seal of the gaskets.
It is advisable to repeat these operations after the appliance
has been running for a few hours and periodically check
the pressure of the system.
A
off.
The unit must be connected to the mains through a multipolar
switch with minimum contact opening of at least 3mm or
with a device that allows the complete disconnection from
the device under the overvoltage conditions category III.
months for some inspections and annually for others, by
the Technical Service Assistance, technically authorised
and prepared, using always original spare parts.
Do not use abrasive sponges or abrasive or corrosive
detergents to avoid damaging the painted surfaces.
When necessary, clean the outer surfaces of the Aquarea
Air cooler-convector with a soft cloth damp cloth.