Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3-WAY VALVE WITH THERMO-ELECTRIC HEAD DIVERTER VALVE KIT
5.4

Mounting

-
Remove the side panel as indicated in paragraph 2.4.
-
Assemble the components as indicated in figure:
-
floor mounted version (fig. 20)
-
wall mounted version (fig. 21) (with optional 3/4" EK
spacer stub pipe)
-
Apply the supplied insulation.
Floor mounted version
1
thermo-electric head (n.1)
2
lockshield (n.1)
3
3-way valve (n.1)
Wall mounted version, with optional 3/4" EK stub pipe
1
thermo-electric head (n.1)
2
lockshield (n.1)
3
3-way valve (n.1)
22
When the hydraulic components have been mounted,
connect the thermo-electric head connectors (ref. X)
with the wiring connectors on the machine (ref. Y).
4
outlet union (n.1)
5
1/2" flexible tube 230 (n.1)
1
3
5
2
4
4
outlet union (n.1)
5
1/2" flexible tube 230 (n.1)
6
3/4'' EK stub pipe (n.1 optional)
1
3
5
6
2
4
53
27
141
100
69
U
I
S

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquarea air 200Aquarea air 700Aquarea air 900

Table des Matières