Troubleshooting; Table Of Anomalies And Remedies - Panasonic Aquarea Air U.M. Manuel D'installation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TROUBLESHOOTING

3.1
Troubleshooting
In case of water leaks or anomalous functioning
immediately cut off the power supply and close the
water taps.
Should one of the following anomalies occur, contact
an authorised service centre or an authorised qualified
person, but do not intervene personally.
3.2

Table of anomalies and remedies

The inspections must be carried out by a qualified installer
or by a specialised service centre.
Effect
A delayed activation of the ventilation
respect to the new temperature or
function settings.
The appliance does not activate the
ventilation.
The ventilation does not activate even if
there is hot or cold water in the hydraulic
circuit.
The appliance leaks water during the
heating function.
There are formations of dew on the
front panel.
There are drops of water on the air
outlet grill.
12
TROUBLESHOOTING
-
-
-
-
-
Cause
The circuit valve needs some time to
open and as a result the hot or cold
water takes time to circulate in the
appliance.
No hot or cold water in the system.
The hydraulic valve remains closed.
The fan motor is blocked or burnt out.
The
micro-switch
that
ventilation when the filter grill is opened
does not close correctly.
The electrical connections are not
correct.
Leaks in the hydraulic connections of
the system.
Leaks in the valve unit.
Thermal insulation unstuck.
In situations of high humidity (>60%)
condensation could form, especially at
the minimum ventilation speeds.
The ventilation does not activate even if there is hot or
cold water in the hydraulic circuit.
The appliance leaks water during the heating function.
The appliance leaks water only during the cooling
function.
The appliance makes an excessive noise.
There are formations of dew on the front panel.
Remedy
Wait for 2 or 3 minutes to open the
circuit valve.
Check that the water boiler or cooler
are functioning correctly.
Dismount the valve body and check if
the water circulation is restored.
Check the working efficiency of the
valve by powering it separately with
230V. If it activates the problem could
be the electronic control.
Check the windings of the motor and
the free rotation of the fan.
stops
the
Check that by closing the grill the micro-
switch contact is activated.
Check the electrical connections.
Check the leak and fully tighten the
connections.
Check the state of the gaskets.
Check the correct positioning of the
thermo-acoustic insulation paying close
attention to the front area above the
finned battery.
As soon as the humidity starts falling
the phenomenon disappears. In any
case the presence of a few drops of
water in the appliance does not indicate
a malfunction.
U
I
S

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Aquarea air 200Aquarea air 700Aquarea air 900

Table des Matières