BLEEDING CLUTCH CONTROL
• Remove the rubber cap 1 from the valve 2.
• Open the sump cap.
• Insert one end of a transparent tube into
a container.
• Pump with the brake lever 2/3 times and
keep the lever pressed.
• Unscrew the valve and let the oil drain.
• If are still visible in the tube repeat above
operation until obtaining a continuous
outflow of oil within no air bubbles.
• Close the valve and release the lever.
NOTE:
During this procedure, continuosly top up
the brake pump thank to replace the oil
that is out flowing.
• Remove the tube.
• Replace the rubber cap.
Use the liquid indicated on page 16 in
the "Recommended lubricants and liquids"
table.
WARNING:
The clutch fluid is extremely corrosive. Take care not to spill it on the paintwork.
Wear appropriate protective clothing and protection gloves.
Keep coolant out of reach of children.
WARNING:
Avoid any direct contact of the liquid with skin, eyes or clothing.
If this happens:
- with the eyes, rinse immediately with plenty of water and seek medical advice.
- with skin, immediately clean contaminated areas with soap and water. Change
clothing that is contaminated with liquid.
If liquid is swallowed, contact a doctor immediately.
51