(see figure 14).
9
Push (1) the dispensing handle and pull the pinch tube end
downwards (2) till it is arranged (see figure 15).
10
Replace the faucet top cover.
5. 4 IN-PLACE SANITIZATION
The In-Place Sanitization prior to starting the machine may
be performed, if needed, only as further precaution, in
addition to the Disassembled Parts Sanitization described
before, but never in lieu of it.
1
Prepare two gallons of a warm (45-60°C, 120-140 °F)
sanitizing solution (100 PPM chlorine residual) according to
your local Health Codes and manufacturer's specifications.
2
Pour the solution into the bowl(s).
3
Using a brush suitable for the purpose, wipe the solution on
all surfaces protruding above the solution-level and on the
underside of the top cover(s).
4
Install the top cover(s) and operate the unit. Allow the
solution to agitate for about two minutes. Drain the solution out
of the bowl(s).
5
Use fresh product to chase any remaining sanitizer from the
bowl(s). Drain this solution. Do not rinse out the machine.
6 ROUTINE MAINTENANCE
Daily: inspect the machine for signs of product leaks past seals
and gaskets. If proper assembly does not stop leaks around
seals or gaskets, check for improper lubrication, worn or
damaged parts. Replace parts as needed with original spare
parts from the supplier.
All manuals and user guides at all-guides.com
figure 14
figure 15
6. 1 MAINTENANCE (TO BE CARRIED
OUT BY QUALIFIED SERVICE
PERSONNEL ONLY)
Montly: clean all internal components, primarily the condenser,
using compressed air.
To clean these internal parts, unplug the unit or switch off the 2-
pole wall breaker, then remove front panel (dispensing side).
Condenser fins are very sharp. Use extreme caution when
cleaning.