A
Tab. 9:
Recommended lubricants
Maintenance
All manuals and user guides at all-guides.com
Maintenance
At tention!
Incorrect lubrication will damage the lock: Do not grease the inside of the lock. Never inject lubricants
into the lock. Do not use resinous greases.
· Only grease the outer sliding surfaces of the lock.
Lubricant
Klübersynth LI 44-22
Fin Lube TF
ASSA ABLOY (Switzerland) AG recommends that maintenance be executed via maintenance contract by an
authorised specialist company to ensure that the following points are fulfilled.
Escape route doors must be inspected for reliable function at intervals of no more than one month.
· Inspect and operate all functions of the lock to ensure that all parts of the locking mechanism (lock and
strike plate) function reliably.
· Check that all parts of the locking mechanism are clean to prevent clogging and obstruction.
· Fire doors must not be altered after installation. Check that no additional locking devices have been
added.
· Check that all components of the system still comply with the list of approved components originally
supplied with the system.
· Check that all control element are securely installed.
· Measure the actuation forces for releasing the escape route door locking mechanism using a force
gauge and log the results. Check whether the actuation forces for releasing the escape route door lock-
ing mechanism have changed significantly since initial installation.
If any of the results are unsatisfactory, please contact your specialist dealer or tradesperson.