Fault
Low battery voltage. The
"> 80%" LED and "Batterie/n
voll" LED light up.
The "Schwach" LED lights up.
(only MT 150 PP and MT 230 PP)
All LEDs are flashing simultane-
ously.
"AES/RE" terminal does not
work.
11 Warranty
The statutory warranty period applies. If the product is defective, please contact your retailer or the manufacturer's
branch in your country (see dometic.com/dealer).
For repair and warranty processing, please include the following documents when you send in the product:
• A copy of the receipt with purchasing date
• A reason for the claim or description of the fault
Note that self-repair or non-professional repair can have safety consequences and might void the warranty.
12 Disposal
Recycling packaging material
➤ Place the packaging material in the appropriate recycling waste bins wherever possible.
Recycling products with non-replaceable batteries, rechargeable batteries or light
sources
➤ If the product contains any non-replaceable batteries, rechargeable batteries or light sources, you
don't have to remove them before disposal.
➤ If you wish to finally dispose of the product, ask your local recycling center or specialist dealer for
details about how to do this in accordance with the applicable disposal regulations.
➤ The product can be disposed free of charge.
EN
Possible cause
No connection from the solar
charge controller to the battery.
Low voltage (< 10.6 V) at the house
battery.
The charging program is not set
correctly.
No excess solar power generated.
Load of connected consumers too
high. Output current exceeded
200 mA.
Solution
➤ Check the connections.
➤ Check the cable cross-sections,
cable lengths and fuses (chapter
"Determine the cable cross-sec-
tions and fuses" on page 19).
➤ Check the stripped cable ends.
➤ Check the voltages directly at the
terminals.
➤ Charge the house battery to
avoid under voltage.
➤ Check the setting of the charging
program according to the battery
type used (chapter "Setting the
charging program" on page 22).
➤ Reduce the connected DC loads.