DESCRIPTION OF THE CONTROL PANEL INPUTS / OUTPUTS
XH08
Security functions control inputs (photocell or light curtains)
safety input (NC), with disconnected circuit - the drive operates in the Trotman
STOP
function (operation with the button pressed)
control input operating according to the settings in MENU
PB2
NO signal control
OPEN
Control input OPEN, NO signal control
CLOSE
Control input CLOSE, NO signal control
control input operating according to the settings in MENU
PB1
controlled by the NO signal
for connecting a photocell or light grille, MENU
PE
the input must be activated
12V/GND
12V DC accessory power output, max load 0.2A