BASIC FUNCTIONS OF THE CONTROLLER
FUNCTION
AUTO CLOSE
FORCE
ADJUSTMENT
CYCLE
COUNTER
RESET TO
FACTORY
SETTINGS
POSITION
DESCRIPTION
Short
NOTE!
press:
The Auto Close function can only be activated if the pho-
tocell or a light curtain has been installed and activated in
MENU 5.
- a short press of the AUTO CLOSE button causes the diode
next to the button to light up and it means that the Auto
Close function is activated.
Default: Auto Close function is triggered when the door is
in the fully open position. The time set for shutdown is 15
seconds. Changes to these settings can be made in MENU
5.
Note!
If the photocell or light curtain detects an obstacle, the door
is automatically closed and the display show E6 error.
- subsequent short press of the AUTO CLOSE button turns
off the diode next to the button which means the Auto
Close function is turned off.
Short press:
- short press: display of the set force
- subsequent short press: display of the force set
- subsequent short presses change the setting forces siły
from
L1: minimum force;
L9: maximum force;
NOTE: L3 to L7 settings are recommended.
Press and
The information will appear on the display
hold the
= OO OO 1O, This example shows that the drive has
button for 6
seconds:
completed 10 cycles.
NOTE:
Cycle counter has 6 digits (max. value is 999999 cycles)
Press and
- This information will appear successively on the display
hold the
F - F = F
button for 10
confirms that the factory settings have been restored.
seconds:
NOTE:
Reset to factory setting is not followed by the counter
reset.
L 1
L 9
to
Then release the button. This information