SETTINGS OF FUNCTION PARAMETERS IN MENU
5. 2
Built-in Infrared
Beam / Light Curtain
identification setting
66
Note
1. Only the (NC) contact is compatible with the
"PE" port terminal.
2. Make sure the infrared beam / light curtain
is properly installed; otherwise, the door may
open but not close.
shown on the display.
5.2
Inspect the correct installation of the photocel-
ls / safety devices before selecting this option.
Select function
Then the display will show:
--
which indicates the need to readjust the
limit positions.
0.-
return to the menu and select the option
of quick limit position adjustment.
Note: the type of protection will be detected
automatically when setting the limit positions.
After the limit position is set, perform an ad-
ditional test:
1. Press the "UP" button to open the door com-
pletely, then press the "DOWN" button to close
the door, manually block the infrared sensor /
light curtain when closing the door; make sure
that the door moves back to the open position
after detecting obstacles.
2. Press the "DOWN" button to close the door
again. If the door can be closed properly, the
built-in IR beam / light curtain identification
function works correctly.
Note
1. Only the (NC) contact is compatible with the
"PE" port terminal.
2. Make sure the infrared beam / light curtain
has been properly installed; otherwise, the door
will be only able to open but not close. An error
appears in the display
E 6.
error code will be
5.2
E 6.