Mechanical installation
Regenerative power supply modules EMB9341 and EMB9342
Mounting of EMB9341-E / EMB9342-E with "push-through" technique
4.2.3
Mounting of EMB9341-E / EMB9342-E with "push-through" technique
In order to reduce the heat generation in the control cabinet, the heatsink of the
regenerative power supply modules EMB9341-E and EMB9342-E can be mounted outside
the control cabinet. Therefore, a mounting frame with seal (accessories) is required.
Distribution of the power loss:
ƒ
– approx. 65 % by separated cooler (heatsink and blower)
– approx. 35 % inside the regenerative power supply
The rated data remain valid.
ƒ
Dimensions
Fig.12-4
Dimensions of regenerative power supply module
a
a1
EMB9341-E
169.5 135 385.5 350
EMB9342-E
169.5 135 385.5 350
92
a
a1
g
c
c1
Dimensions of EMB9341-E and EMB9342-E for mounting in push-through technique
b
b1
c
c1
d
[mm]
117 152.5 366 105.5 250
117 152.5 366 105.5 250
f
e
Assembly frame
d1
e
f
g
Order no.
92
6.5
92
6.5
9340vrm015
Mounting cutout
Height
Width
[mm]
EJ0038
350 ±3
139 ±3
EJ0038
350 ±3
139 ±3
EDBMB9340 DE/EN/FR 9.0