Electrical installation
Regenerative power supply module EMB9343
Control connections
5.4.2
Control connections
Terminal assignment
E1
39
Fig.13-11
Digital outputs
Terminal
X2/A1
X2/A2
Note!
Integrate terminal X2/A1 and X2/A2 into the release cascade of the drive
system.
Digital inputs
Terminal
X2/E1
Voltage supply
Terminal
X2/39
X2/59
Screw terminal data
Terminal data
Flexible
With wire end
ferrule
122
22 k
10 R
V > 30 V
R
934x
A1 A2
Digital inputs and outputs
Use
General fault indication
Mains failure
Use
Inhibit feedback operation
Use
Reference potential for terminal 59
Connection of the supply voltage for the digital outputs
Conductor cross-section
2
[mm
]
2.5
59
Level with activated output
LOW
LOW
Level with activated input
HIGH
[AWG]
[Nm]
12
9340vrm007
Data
LOW level: 0 ... +5 V
HIGH level: +11 ... +30 V
Short-circuit-proof
Output current:
Output current:
max. 50 mA per output
(external resistance > 480 Ohm
with 24 V)
Data
LOW level: 0 ... +5 V
HIGH level: +11 ... +30 V
Input current with 24 V: 8mA
Reading and processing of the
input: once per 1 ms (average)
Data
DC 24 V, min. 100 mA
,
Tightening torque
[lb-in]
0.5
4.4
EDBMB9340 DE/EN/FR 9.0