3.3
LCD DISPLAY _____________________________________________________________
The LCD displays current functional values for the
operation of the Eclipse mower and sounds one of three
types of audible alerts. The LCD operates in one of two
modes, Operator Mode (Default), and Maintenance
Mode. Use of Maintenance mode requires a four digit pin
number.
Press either of the orange buttons (K or L) to change
screen display or change values. Push the right orange
button (K) to go forward in the display list or increase
setting value, and push the left orange button (L) to go
back in the display list or decrease setting value. The
black button (J) is used to select, reset, or change
values.
K
Audible Alerts indicate one of three conditions detected
by the LCD Display and a corresponding message would
show on the display. A solid tone indicates low system
voltage. A fast beeping (2 per second) alert indicates an
over voltage condition. A slow beeping (1 every 3
seconds) alert indicates mower is in backlap mode.
Alert Displays: In addition to the standard displays for
each mode, there are four displays that are used to alert
the operator/mechanic of a problem the needs to be
corrected.
Alert Displays
LOW BATTERY
41.8 VDC
OVERVOLTAGE
CHECK VOLTAGE
Low Voltage display is shown when system voltage
drops below 42 Volts DC for 30 seconds and an solid
tone alarm will sound. Press the black button (J) to
silence the alarm. Return mower to storage area or
install a fully charged battery pack. Reel motor will
not operate with low voltage on the display.
Overvoltage/Check Voltage display is shown when
system voltage is above 60 Volts DC and a fast (2
per second) beeping alarm will sound. If not
corrected, controller will shut down after 60 seconds.
Check generator output before restarting system.
[See Section 9.3].
All manuals and user guides at all-guides.com
G
L
J
Figure 3B
REEL
MOTOR FAULT
TRACTION
MOTOR FAULT
Figure 3C
Reel Motor Fault display is shown when a reel
motor short circuit is detected or the reel motor
current draw exceeds 30 Amps for one second. Reel
motor will not operate until the problem is resolved.
Return mower to maintenance area for repair.
!
WARNING
Turn reel switch off, release bail, turn key to off
position, and disconnect battery connector before
checking for obstructions in reel.
Traction Motor Fault display is shown when a
traction motor short circuit is detected or the traction
motor current draw exceeds 30 Amps for one
second. Traction motor will not operate until the
problem is resolved. Return mower to maintenance
area for repair.
Operator Mode is used by the operator for system
voltage information, travel speed, FOC setting, and reel
speed. Press the orange buttons (K and L) on the front
handle cover to toggle between the different displays.
Operator Mode is view only, no system settings can be
changed.
If reel switch is placed into backlap position while in
operator mode, the reel motor will stop immediately, and
screen will display "Turn Backlap Switch Off". Backlap is
only available in Superintendant Mode.
Standard start up
screen.
Displays system
voltage.
Displays travel
speed of mower.
Displays fixed FOC
setting.
Displays reel rotation
speed.
Display if Reel Switch
is placed in backlap
position.
CONTROLS
JACOBSEN
VERSION 1.27
SYSTEM VOLTS
48.0 VDC
TRAVEL SPEED
3.4 MPH
FOC = 0.146
REEL SPEED
2200 RPM
TURN BACKLAP
SWITCH OFF
Figure 3D