NOTE
NOTE
Siemens AG
6SE7087-7JP50
SIMOVERT MASTERDRIVES
The specified bus address must be the same as that of the
parameterized SST bus address in SIMOVERT MASTERDRIVES
(P700).
No bus address is assigned to the drive with the button "Disconnect
network connection".
Field "Number of PCD" has no special significance for the
parameterization of MASTERDRIVES and should be left at "2".
If the value is changed, it must be/remain ensured that the setting value
in the program matches the value in parameter P703 of the drive at all
times.
Fig. 8-11
Create file; Drive properties
After confirming the drive properties with ok you have to enter the name
and storage location of the download file to be created.
Operating Instructions
Parameterization
8-17