Installation
Reassemble device
Mount device
Connecting up the
unit
Designating the
optional board
5-12
♦ Place the front of the device with the electronics board to the left
next to the device. Connect the ribbon cable again with the
electronics board and the power section and close the lock on the
connector.
♦ To start with, hold the front of the device with the left-hand side
panel tilted to the right at an angle of approx. 30° and place this unit
on the front of the device. Be careful not to damage the insulating
film on the right-hand inner side panel and to position the left-hand
side panel through the fixing lug correctly on the left housing side.
Applying little pressure, you can then insert the front cover and the
side panel in the housing, in parallel to the right-hand side panel.
The fold on the left-hand side panel as well as the detent lugs on the
right-hand side of the housing noticeably snap in.
♦ For less load on the connection points, put the device down on the
right-hand side and screw in the two screws each on the top and
bottom-side of the device for some turns only. Now tighten all four
screws.
♦ Now replace the housing of the DC link busbars until it noticeably
snaps in.
♦ Push the device from the front, below the DC link busbars, to its
mounting position.
♦ Lift the device until the DC link busbars are fully connected again.
♦ Screw in the fixing screws to firmly tighten the device onto the
mounting surface.
♦ Lock in the DC link busbars.
If you are using an AC device as a single drive, you may fix the device
directly on the mounting surface.
♦ Re-connect all previously removed connecting cables.
♦ Check all connecting cables and the shield to make sure they sit
properly and are in the correct position.
♦ To designate the optional board, insert the relevant designation
plate into the envisaged position on the front of the unit.
♦ After powering up the voltage, you can log on the optional boards in
the software of the unit and commence start-up.