Turn the laser function on/off using B↓; B↑
To end the process, press the A↑ button once
The laser will be activated when the imbalance position has been
reached.
This means that the adhesive weight can be affixed in the 6 o'clock
position.
2.9.9.
The machine MUST be calibrated after securing and at a minimum before the season or after a longer
period of use.
First, select lorry mode using the model button.
Clamp a wheel that has already been balanced (e.g. 22.5") and
enter the wheel values (see use).
In order to access the calibration system, you must press the key
combination shown opposite:
First the C button and then the T button
The [CAL] – [CAL] displays will appear and the indicator lights
flash.
Release the buttons only when the indicator light is steady.
The balancing process for the calibration starts when you press the
START button or close the wheel protector.
The display shown opposite appears after the balancing process.
Attach the calibration weight (200 g) to the inside of the wheel rim.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2022-07
Calibrating the weight sensors in lorry mode
Manufacturer ATH-Heinl GmbH & CO.KG
- 29 -