Filter cleaning
In season when the device is used regularly, clean the filter every two weeks.
1.
Make sure the device is switched off and the plug is removed from the power outlet
(Figure 16, pos. 1).
2.
The device has two filters on the back. Open the top grill with a click system, the bottom
grill with screws and remove the filters.
3.
Carefully vacuum the filters.
4.
The filters can be cleaned with lukewarm clean water.
5.
Let the filters dry completely prior to returning it to its place.
Never use the device without the filters.
End-of-season cleaning
1.
Completely remove the condensed water via the water discharge point.
2.
Run the device on the fan function for 2 hours.
3.
Switch off the device and remove the plug from the power outlet.
4.
Clean and replace both filters.
5.
Remove the hot air outlet hose from the device.
6.
Remove the batteries from the remote control. (Figure 15).
Troubleshooting
The device does not
start when the ON/OFF
button is pressed
The device does not
seem to do much
The device produces
noise
The device leaks water
The device switches
itself OFF
Error code Ft
Error code E0/E1/E2
Disposal
At its end of life, discard the device according to the local laws and
regulations, or deliver the device to your supplier. Remove the batteries
from the remote control for separate disposal.
Is the plug connected to the power socket? Is the earth leakage
circuit breaker switched on? Is there a power outage? Could the
water tank be full? Empty the water tank. The room temperature
is lower than the set temperature; adjust the set temperature.
Measure the outlet temperature; it should be ± 10° cooler than
the room temperature. Is there direct sunlight? Close the curtains.
Are windows and/or doors open? Close them. Are there too many
people in the room? Is the room too big? Is there something in the
room that produces (a lot of) heat? Turn it off or delete it. Is the
filter dusty, covered with dirt? Clean it. Is the air inlet or outlet
blocked? Provide free airflow.
Is the surface of the machine firm, level and horizontal? The
flowing refrigerant in the unit also produces some noise. This is
normal.
Is the water drain hose installed correctly? Is the leakage due to
moving the device with a full water tank? Then empty the water
reservoir first. Check the tap on the drain and the water discharge
point.
The overheating protection may have turned it off. See 'Safety'.
The water tank is full. See 'Drainage of condensed water'.
Contact your supplier.