Dea NET EXP Notice D'emploi Et Avertissements page 19

Carte d'extension entrées/sorties
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 31
7 INPUTS AND OUTPUTS DESCRIPTION
The tables below provide a description of the functioning of all possible selections for both the inputs and the outputs on the NET_EXP
board. Also refer to the table confi guration parameters.
SELECTION
NONE
Not used.
N.O. input start. In case of action, this results in the opening or closing. It may function in "inversion"
START
(P049=0) or "step-by-step" (P049=1) modality.
N.O. pedestrian start. In case of action, this results in the partial opening of the gate. The adjustment of the
PED.
pedestrian pace can be set with P043.
N.O. input open. In case of action, this results in the partial opening of the gate. It may function in "inversion"
OPEN
(P049=0) or "step-by-step" (P049=1) modality.
N.O. input close. In case of action, this results in the closing of the gate. It may function in "inversion"
CLOSE
(P049=0) or "step-by-step" (P049=1) modality.
OPEN_PM
Dead man N.O. input open The gate opens for the amount of time in which the button is pressed.
CLOSE_PM
Dead man N.O. input close The gate closes for the amount of time in which the button is pressed.
Electric lock activation N.O. input. In case of action, this leads to the activation of the "LOCK" output of the
ELOCK_IN
board, see P062.
Photoelectric cell 1 N.C. input. See P050 to select the operation mode. If this is not used, bridge out the
PHOTO 1
connection.
Photoelectric cell 2 N.C. input. See P051 to select the operation mode. If this is not used, bridge out the
PHOTO 2
connection.
Sensitive edge 1 N.C. input. See P067 to select the operation mode. If this is not used, bridge out the
SAFETY 1
connection.
N.C. contact. (SAS INPUT): If connected to WARN_FIX/SAS OUTPUT of a second control unit, causes the "bank
door" to operate (disabling the opening of the second door until the fi rst is not fully closed).
STOP (SAS INPUT)
Stop N.C. input. In case of action, this stops the movement during any manoeuvre. If this is not used, bridge
out the connection.
FCA1
Motor 1 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
FCA2
Motor 2 opening end stop N.C. input If not used, disable the input with the corresponding parameter.
FCC1
Motor 1 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
FCC2
Motor 2 closing end stop N.C. input If not used, disable the input with the corresponding parameter.
Sensitive edge 2 N.C. input. See P068 to select the operation mode. If this is not used, bridge out the
SAFETY 2
connection.
Starts the operation and enables the green light ignition (arrival at open gate) only for the internal traffi c
OPEN_INT
light. Meanwhile, if the OPEN_EXT command is given, this books the next operation and the green light of the
external traffi c light turns on at the end of the Automatic Closing Time (ACT).
Starts the operation and enables the green light ignition (arrival at open gate) only for the external traffi c
OPEN_EXT
light. Meanwhile, if the OPEN_INT command is given, this books the next operation and the green light of the
internal traffi c light turns on at the end of the Automatic Closing Time (ACT).
AUX_IN
Input for the control of the AUX_OUT output.
INPUTS
DESCRIPTION
17

Publicité

Chapitres

Table des Matières
loading

Table des Matières