General Information; Technical Specifications; Control Unit - BFT SP 3500 Instructions D'utilisation

Actionneur pour portails coulissants á crémaillère
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 15

1) GENERAL INFORMATION

The SP3500 operator consists of a strong gearmotor.
The self-braking motor and irreversible gearbox allow the gate to stop quickly,
avoiding uncontrolled sliding of the gate due to the effect of inertia.
The gearmotor is coupled to the gate by means of a rack. The control panel is built
in and comprises: start relay, three-phase motor protector, control unit.
The operating logic provides for various configurations so that use of the automa-
ted device can be tailored to the user's needs (e.g.: automatic closing, controlled
closing, photocells active during closing etc.). To edit settings, call in qualified
personnel (installer).
The irreversible gearmotor keeps the gate locked closed, meaning there is no
need to use solenoid locks.
A manual release system allows the gate to be opened manually in the event of
a mains power outage or malfunctioning.
We recommend fitting a shock absorber profile.

2) TECHNICAL SPECIFICATIONS

SIRIOTEL 400: 3-phase + N 380-400V ~ 50/60Hz
Power supply*
SIRIOTEL 230: 3-phase + 220-230V ~ 50/60Hz
Power demand
0.55 kW
Max. current demand
2A (380-400V); 3A (220-230V)
Protection
motor protector wired in panel
Insulation class
F
Reduction ratio
1/50
Pinion module
m=6mm z=19 teeth
Maximum leaf weight
35000N (≈3500kg)
Leaf speed
10.5 m/min
Impact reaction
stop (with safety edge)
Gearbox lubrication
oil
Manual operation
key-operated mechanical release

Control unit

SIRIO TEL with interface
Environmental conditions from -15°C to +50°C
Protection rating
IP 54
Dimensions
Fig. J
Operator weight
54 kg.
Max. travel
30 m
Out speed
28 rpm
Use
100% up to 2200 kg. / 60% over 2200 kg.
CONTROL UNIT
Power supply
3-phase + N 380-400V~: 3-phase 220-230V~ 50/60 Hz
Low voltage/mains insulation > 2MOhm 500V
LV/mains dielectric rigidity 3750V~ 1'
Accessories power supply 24V~/0.5A
Gate open light
24V/3W
(*) Special supply voltages to order.
(*) 3-phase 220-230V power supply available.
3) TUBE ARRANGEMENT Fig.A
Install the electrical system referring to the standards in force for electrical systems CEI
64-8, IEC 364, harmonization document HD 384 and other national standards.
4) PREPARATION FOR MOTOR MOUNTING FIG. B-K
• Make a hole in the ground to accommodate the concrete pad, with anchors
embedded in the base plate for fastening the gearbox assembly, keeping to the
distances featured in FIG.B.
5) MOUNTING THE MOTOR FIG.C
6) MOUNTING DRIVE ACCESSORIES FIG.D-D1
7) RACK CENTRING WITH RESPECT TO PINION FIG.L
DANGER - Welding must be performed by a competent person issued
with the necessary personal protective equipment as prescribed by
the safety rules in force.
8) FASTENING LIMIT SWITCH BRACKETS FIG.E
9) STOPS FIG.M
DANGER - The gate must be fitted with mechanical stops to halt its
travel both when opening and closing, thus preventing the gate from
INSTALLATION MANUAL
MOTOR
coming off the top guide. Said stops must be fastened firmly to the ground,
a few centimetres beyond the electric stop point.
10) MANUAL RELEASE (See USER GUIDE -FIG.2-).
Warning: do not JERK the gate open and closed, instead push it GENTLY to
the end of its travel.
11) MOTOR PROTECTOR FIG. N
Make sure it is set for the motor's rated current demand (380-400V/2A) (220-
230V/3A).
12) CHECKING DIRECTION FIG.N1
Release the motor and move the gate half way along its travel. Relock the motor
then turn the power off and back on. Give the start command. If the gate does
not move in the opening direction, swap the phase wires over. WARNING: also
check that limit switches SWO-SWC are working properly.
13) TERMINAL BOARD WIRING FIG. F-G
Once suitable electric cables have been run through the raceways and the automa-
ted device's various components have been fastened at the predetermined points,
connect them as directed and illustrated in the diagrams contained in the relevant
instruction manuals.
Connect the live, neutral and earth wire (compulsory) Fig. Q-R.
TERMINAL
DEFINITION
Three-phase power supply 380-400V~, 50-60Hz
1
N
N NEUTRAL
2
R
R LINE 1
3
S
S LINE 2
4
T
T LINE 3
Three-phase power supply 220-230V~, 50-60Hz
R
2
R LINE 1
3
S
S LINE 2
4
T
T LINE 3
BLINK 230V
8-9
Flashing light 230V output max. 40W.
Free contact (N.O.).
SCA
10-11
Gate Open Light output SCA 24V~ max. 3W.
24V AUX ~
11
Accessories power supply:
24V~ operation with mains power on.
0V AUX ~
12
Safety device power supply output (photocell transmit-
Vsafe -
12
ter and safety edge transmitter).
N.B.: output active only during operating cycle.
Vsafe +
13
24V~ Vsafe operation with mains power on.
LOOP 1
14
Safety device test input LOOP 1 (see fig.G)
15
LOOP 2
Safety device test input LOOP 2 (see fig.G)
Free contact (N.O.).
2°CH.R
16-17
2nd radio channel output. 24V~ max. 3W.
Antenna (18 signal - 19 braiding).
Use an antenna tuned to 433MHz. Use RG58 coax cable
ANT
18
to connect the Antenna and Receiver. Metal bodies
19
SHIELD
close to the antenna can interfere with radio reception.
If the transmitter's range is limited, move the antenna to
a more suitable position.
INPUTS OF
20-21-22
TESTED
Tested safety device connection (see fig.O-P)
DEVICES
INPUTS OF
23-24-25
TESTED
Tested safety device connection (see fig.O-P)
DEVICES
START command input (N.O.).
26-27
START
Operation according to 2-4-step logic.
STOP input (N.C.)
26-28
STOP
The command stops movement.
If not used, leave jumper inserted.
PHOTOCELLinput (N.C.) Operation according to photocell
26-29
PHOT
during opening logic. If not used, leave jumper inserted.
Opening limit switch SWO (N.C.). If not used, leave jumper
SWO
26-30
inserted.
Closing limit switch SWC (N.C.). If not used, leave jumper
26-31
SWC
inserted.
PEDESTRIAN command input (N.O.)The command causes
PED
26-32
the automated device to open to the pedestrian opening
position.
OPEN command input (N.O.).The command causes the
leaves to open. If the contact stays closed, the leaves
26-33
OPEN
stay open until the contact is opened. When the contact
is open, the automated device closes following the TCA
time, where activated.
CLOSEcommand input (N.O.).
CLOSE
26-34
The command causes the leaves to close.
Safety edge input BAR (N.C.).
26-35
BAR
The command reverses movement for 2 sec.
If not used, leave jumper inserted.
36
Not used
Not used
40-53
See wiring fig. Q-R
DESCRIPTION
13
SP 3500 -

Publicité

Table des Matières
loading

Table des Matières