11.2 Reset of water litres count for softener regeneration
1) Turn the programming switch to ON;
2) Simultaneously press the 4 keys PROG
of the left push button panel until the display shows the signal.
3) to bypass regeneration control, set a value of 00000 litres.
11.3 Resetting selection count to zero
1) Turn the programming switch on OFF;
2) Keep the PROG key
3) Turn the programming switch on ON;
4) Press the key
to start the zero setting;
5) Press the UP ARROW key
i
The above procedure allows resetting to zero of the counts of each push button panel while leaving the
total counts of the machine unchanged (life cycle of the machine).
S
12.
ignals
1,1 bar
120°C
boiler filling
1,1 bar
120°C
filling timeout
doser alarm
reg. softener
i
If the machine will not work call technical assistance.
pressed for 5 seconds;
for at least 3 seconds to confirm the zero setting.
cause
Boiler filled with water when using the machi-
ne for the first time or when refilling to reach
the water level.
Time for filling the boiler with water longer
than expected.
Fault of the volumetric electronic control
Water softener regeneration request
reg. softener
reg. softener
total coffees
reset counting ?
press + 3 sec.
solution
Wait for the boiler to be completely filled.
Make sure the water mains cock is opened.
Switch the machine off and back on again.
If the warning is still on after a few at-
tempts, call Technical Assistance.
Stop delivery by pressing the dose key. Call
the Technical Assistance.
Carry out the water softener regeneration.
To put off the warning turn the program-
ming switch on ON and press simultane-
ously the 4 display keys
for 5 seconds
SAE - DISPLAY
00000
00000
00000000
data reset
29