 The network addresses of the control boards and the « ID » of the radio of each column must
be spotted on a plan to configure the alarms assignment on the MAXIBUS III Hub. (See
NT297 of the MAXIBUS III Hub)
Example: The intrusion alarm zone 1 is detected by the RX column address 3 and transmitted to the
MAXIBUS III Hub via the radio ID 425.
TX column
TX control board address: 1
Radio ID : 210
Note : in the case of 2.5 m / 8.2 ft and 3 m / 10 ft barriers, the radio transmits 1 alarm information per
control board. It is possible to associate these information in the MAXIBUS III Hub to have only
one alarm information on the same relay.
8

FINAL TESTS

After installation, verify correct operation with a complete test:
 Cut two adjacent cells and check the activation of the intrusion alarm. (Red indicator
light on the RX column)
 If the mono-detection is activated, cut the lower cell and check the activation of the intrusion
alarm. (Red indicator light on the RX column)
 Mask one of the cells for 1min and check the activation of the disqualification alarm. (Red
light flashing on the RX column)
Note: The visualisation of the alarms using the red indicator light of the RX column is only possible
when the column is open. (Tamper output open)
Zone 1
RX/TX column
TX control board address: 2
RX control board address: 3
Radio ID : 425
Zone 2
RX/TX column
TX control board address: 4
RX control board address: 5
Radio ID : 398
- 48 -
SOLARIS
Zone 3
RX column
TX control board address: 6
Radio ID : 1328