Special Functions - CAME PXC99W Manuel De Programmation

Masquer les pouces Voir aussi pour PXC99W:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Call delay
(▲)/(▼)
CALL DELAY
[0..255]S 000
You can set a delay on the activation of the telephone dialler fol-
lowing an event in order to avoid telephone calls caused by false
alarms
In telephone options STOP FROM CODE MUST be activated
Example: delay set at 10 s. If an input is unbalanced
in error, but a valid user code is entered within 10 sec-
onds, the telephone call will not be made. Conversely
if more than 10 seconds elapse the telephone call will
be made as usual.
Displaying GSM field
(▲)/(▼)
Displaying the GSM signal power as shown below:
No signal
----
Low signal
#---
Medium signal
##--
Good signal
###-
Excellent signal
####

Special functions

The valid procedure for managing special functions, after accessing
the Installer/Technical menu, is as follows:
and with
SPECIAL 21 FUNCTIONS
(▲)/(▼)
(*)
tion to change and press
The display illustrated always shows
(*)
the default value of the property With
Keypads display
KEYPADS DISPLAY
(▲)/(▼)
AREA STATUSES
The keypads are made up of two rows of 16 characters The date
appears in the first row and in the second you can decide what to
display from the following information
Shows the name of the keypad
KEYPAD NAME
Shows whether the single areas are on/off
AREAS STATUS
Shows one of the system's on/off statuses: OFF, TO-
SYSTEM STATUS
TAL ARMING, PARTIALISED
Shows the fixed message ENTER CODE
ENTER CODE
Displaying open inputs
(▲)/(▼)
DISP.OPN.INPUTS
DISABLED
Lets you enable/disable displaying the open inputs with the control
unit disarmed
(+)/(-)
GSM SIGNAL FIELD
[0..4] ###-
select the special func-
(▲)/(▼)
you can exit at any time
(#)
(+)/(-)
(+)/(-)
Printer output enabled
(▲)/(▼)
PRINTER OUTPUT
ENABLED
Lets you activate the printer output for continuous printouts of
events on the RS-232
The serial port setting is: Bits per second 9600; Data bits 8; Parity
N; Bit stop 1
Example: connect the control unit to the PC with an
RS-232 direct cable. Open a serial port receiving pro-
gram (Windows Hyper Terminal for example) and set
the COM port.
Arming control unit after REBOOT C U
REBOOT C.U.
(▲)/(▼)
PREVIOUS STATUS
It is possible to set the on/off status of the control unit after a Re-
boot C U (restart)
All the areas are on
TOTAL ARMING
All the areas are off
TOTAL DISARMING
The on/off status of the areas goes back to the one
PREVIOUS STATUS
preceding Reboot C U
Quick arming
QUICK TURN ON
(▲)/(▼)
DISABLED
If activated it lets you start scenarios from the keypads without hav-
ing to enter a code
Screening control unit status
SEE AREAS STATUS
(▲)/(▼)
[0..30] SEC 000
To set the time after which the on/off status of the areas is screened
(hidden) on the keypads and readers (
Pre-arming test
PRE ENTER TEST
(▲)/(▼)
DISABLED
If activated, during system arming, when there are anomalies (no
telephone line, no communication with at least one system device,
etc ) the keypad will display
WANT TO PROCEED?
abandon arming the system or press the
The forced arming will, however, be recorded in the events memory
Supervision repetition
RETRY SUPERV.
(▲)/(▼)
DISABLED
Lets you send repeated notifications of the anomaly of no supervi-
sion of radio inputs
(+)/(-)
(+)/(-)
(+)/(-)
(+)/(-)
= NOT SCREENED)
000
(+)/(-)
, press the
key to
(#)
key to go ahead anyway
(*)
(+)/(-)

Publicité

Table des Matières
loading

Table des Matières