Les langues disponibles

Gong output time
GONG
OUTPUT
[0..255] SEC 000
The Gong alarm condition is determined by activations of the inputs
which have their "Gong Output" property set to ON
Exit time
EXIT
TIME
[0..255] MIN 050
During the exit time the control unit checks the conditions of the
exits and warns if there are open inputs on the keypads (visual and
acoustic) and on the reader LEDs
Entry time 1 and 2
ENTRANCE TIME 1 01
[0..255] MIN 030
ENTRANCE TIME 2 01
[0..255] MIN 040
When the system is armed, unbalancing of a Delayed 1 or 2 type
input activates the respective entry time counter During the entry
time, the control unit does not trigger an alarm if Path or Delayed
inputs are unbalanced
At the end of the entry time, if the system is not disarmed, a general
alarm is triggered
When the time is greater than 45 seconds, the reference
standard is invalidated
Rounds time
ROUNDS TIME
[0..1800] S
This function allows a code or key to inhibit the areas associated
with them for the time set
During this time the activation of one or more inputs belonging to
these areas does not trigger an alarm
With the control unit armed, key in the rounds code and press key
or use the decoded key to initialise the rounds time set
(D)
On the keypad display, in place of the symbol
or
(area partially armed), the symbol
(P)
the areas associated with the code or key will be inhibited When
the timer set runs outs, the areas return to being protected To
end the rounds early just enter a valid code and press button
approach a valid key to the reader
When the rounds function starts up the
in the control unit log and when it finishes, the
also saved
On the first row of the LCD keypad's display, with the screening
function not active, the time to the end of the rounds is shown
30 seconds before the end of the rounds the keypad and reader
buzzers are activated continuously
01
(+)/(-)
01
(+)/(-)
(+)/(-)
(+)/(-)
XXX
(+)/(-)
(area totally armed)
(#)
will appear; for this time
(R)
or
(A)
event is saved
START ROUNDS
event is
END ROUNDS
Telephone notifications
The valid procedure for all programming of telephone notifications,
after accessing the Installer/Technical menu, is as follows:
(▲)/(▼)
TELEPHONE 14 NOTIFICATIONS
which to programme a telephone notification
PHONE NOT. MENU 01 GENERAL ALARM
PHONE NOT. MENU 02 SABOTAGE
PHONE NOT. MENU 03 TECHNICAL ALARM
PHONE NOT. MENU 04 BURGLARY ALARM
PHONE NOT. MENU 05 ON/OFF
PHONE NOT. MENU 06 FAILURES
PHONE NOT. MENU 07 ENTER CODES
PHONE NOT. MENU 08 ENTER KEYS
PHONE NOT. MENU 09 INPUTS ALARM
PHONE NOT. MENU 10 VARIOUS
and press
Then with
browse through the options
(*)
(▲)/(▼)
The display illustrated always shows the default value of the prop-
erty (
= telephone enabled,
= telephone disabled) With
#
-
exit at any time
System alarm
activation
S Y S . A L R M . A C T V S
########
(1)....(8)
Telephone notifications associated with the activation and restora-
tion of the system's general alarm
With number keys
select the phones to associate with the
(1)
(8)
notification
Example:
means that telephones 3 and 5 are
--#-#---
enabled and the others aren't.
Single areas' alarm
activation
AREA ALRM. ACTV 01
--------
(1)....(8)
Telephone notifications associated with the activation and restora-
tion of the single areas' alarm
With number keys
select the phones to associate with the
(1)
(8)
notification
Example:
means that telephones 3 and 5 are
--#-#---
enabled and the others aren't.
System sabotage alarm
activation
SYS. SABOTG. ACTVS
########
(1)....(8)
Telephone notifications associated with the activation and restora-
tion of the system's sabotage alarm
With number keys
select the phones to associate with the
(1)
(8)
notification
Example:
means that telephones 3 and 5 are
--#-#---
enabled and the others aren't.
, with
choose the event for
(*)
(▲)/(▼)
you can
(#)
restoration
S Y S T . A L R M . R S T S
--------
(1)....(8)
restoration
AREA ALRM. RSTS 01
--------
(1)....(8)
restoration
SYS.
SABOTG.
RSTS
--------
(1)....(8)

Publicité