Voltage Supply - Lenze LECOM-B E82ZAFLC001 Instructions De Montage

Module de fonction
Table des Matières

Publicité

6
Electrical installation

Voltage supply

Voltage supply
)
Note!
In the case of an external voltage supply and for greater distances between the
control cabinets, always use a separate power supply unit (SELV/PELV) that is
safely separated in accordance with EN 61800−5−1 in each control cabinet.
DC voltage supply
Internal
The internal voltage is provided at terminal X3.3/20. It serves to supply the
controller inhibit (CINH).
External
The external voltage supply of the function module is required if communication is
to be maintained during a failure of the standard device supply.
X3/
Designation
+
A
T/R(A)
B
T/R(B)
CN
CNTR
VP
40
GND3
7
GND1
39
GND2
28
CINH
20
59
*) e.g. if a repeater is connected
46
Function
Additional HF−shield termination
RS485 data line A
RS485 data line B
*)
*)
Reference potential for LECOM−B
network *)
Reference potential for the internal
supply at X3/20
Reference potential of controller inhibit
(CINH) at X3/28
Controller inhibit
DC voltage source for internal supply of
controller inhibit (CINH)
External DC supply for the function
module
l
Level
During data transmission:
CNTR = HIGH
+5 V (reference: GND3)
+5 V (reference: GND3)
l
Start = HIGH (+12 ... +30 V)
l
Stop = LOW (0 ... +3 V)
+20 V (reference: GND1)
±
U(ext.) = +24 V DC
10%
(reference: GND1)