Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

EDK82ZAFIC−010
.MiR
INTERBUS PT
E82ZAFIC010
Funktionsmodul
Function module
Module de fonction
Montageanleitung
Mounting Instructions
Instructions de montage
l

Publicité

Table des Matières
loading

Sommaire des Matières pour Lenze INTERBUS PT

  • Page 1 EDK82ZAFIC−010 .MiR Montageanleitung Mounting Instructions Instructions de montage INTERBUS PT E82ZAFIC010 Funktionsmodul Function module Module de fonction...
  • Page 2 Lesen Sie zuerst diese Anleitung und die Dokumentation zum Grundgerät, bevor Sie mit den Arbeiten beginnen! Beachten Sie die enthaltenen Sicherheitshinweise. Please read these instructions and the documentation of the standard device before you start working! Observe the safety instructions given therein! Lire le présent fascicule et la documentation relative à...
  • Page 3 E82ZAFI014B...
  • Page 4 Legende zur Abbildung auf der Ausklappseite Pos. Beschreibung Ausführliche Information ^ 32 LED (gelb): Status der INTERBUS−Kommunikation LED (grün): Verbindungsstatus zum Antriebsregler ^ 30 DIP−Schalter S1 Einstellung für den letzten Busteilnehmer = OFF Einstellung für alle anderen Busteilnehmer = ON DIP−Schalter S2 ...
  • Page 5: Table Des Matières

    Inhalt Über diese Dokumentation ..........Sicherheitshinweise .
  • Page 6: Über Diese Dokumentation

    Softwarestand INTERBUS PT E82ZAFIC010 Zielgruppe Diese Dokumentation wendet sich an Personen, die das beschriebene Produkt nach Projekt- vorgabe installieren und in Betrieb nehmen. Tipp! Informationen und Hilfsmittel rund um die Lenze−Produkte finden Sie im Download−Bereich unter http://www.Lenze.com EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 7: Sicherheitshinweise

    Sicherheitshinweise Sicherheitshinweise Gefahr! Unsachgemäßer Umgang mit dem Funktionsmodul und dem Grundgerät kann schwere Personenschäden und Sachschäden verursachen. Beachten Sie die in der Dokumentation zum Grundgerät enthaltenen Sicherheitshinweise und Restgefahren. Stop! Elektrostatische Entladung Durch elektrostatische Entladung können elektronische Bauteile innerhalb des Funkionsmoduls beschädigt oder zerstört werden.
  • Page 8: Produktbeschreibung

    Produktbeschreibung Funktion Produktbeschreibung Funktion Das Funktionsmodul koppelt das Grundgerät an das Kommunikationssystem INTERBUS. Bestimmungsgemäße Verwendung Das Funktionsmodul ... ƒ ist eine Zubehör−Baugruppe, die mit folgenden Lenze−Grundgeräten eingesetzt werden kann: Produktreihe Gerätebezeichnung ab Hardwarestand Frequenzumrichter 8200 vector Vx14 ƒ ist ein Betriebsmittel zum Einsatz in industriellen Starkstromanlagen.
  • Page 9: Lieferumfang

    Produktbeschreibung Lieferumfang Lieferumfang E82ZAFI014B, AFX006/007/011/012 Pos. Lieferumfang Funktionsmodul E82ZAFIC010 Montageanleitung 2 Steckerleisten mit Federkraftanschluss, 3−polig Steckerleiste mit Federkraftanschluss, 13−polig Befestigungsbügel (Verwendung siehe Betriebsanleitung/Montageanleitung 8200 vector) EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 10: Identifikation

    Produktbeschreibung Identifikation Identifikation ‚ƒ  ‚ƒ A22 APPLICATION APPLICATION 010 / 3A22 010 / 3A22 Type Id.-No. Prod.-No. Ser.-No. E82AF000P0B201XX E82ZAFX005  ‚ ƒ E82ZAF Produktreihe INTERBUS Gerätegeneration Variante: PT (Plug Terminal) mit Feder- kraftanschluss Hardwarestand Softwarestand EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 11: Technische Daten

    Technische Daten Allgemeine Daten Technische Daten Allgemeine Daten Bereich Werte Bestell−Bezeichnung E82ZAFIC010 Kommunikationsmedium RS485 Netzwerk−Topologie Ring (Hin− und Rückleitung im selben Kabel) Anzahl Teilnehmer Abhängig vom INTERBUS−Master (z. B. Phoenix Contact G4−Master). Für folgende Angaben gilt in Abhängigkeit mit/ohne PCP−Kommuni- kation der jeweils kleinere Wert: mit PCP−Kommunikation: maximal 62 oder ohne PCP−Kommunikation: maximal 256/Anzahl PZD...
  • Page 12: Einsatzbedingungen

    IEC/EN 60721−3−1 1K3 (−25 ... +60 °C) Transport IEC/EN 60721−3−2 2K3 (−25 ... +70 °C) Betrieb Entsprechend der Daten des verwendeten Lenze Grundgerätes (siehe Dokumentation des Grundgerätes). Verschmutzung EN 61800−5−1 Verschmutzungsgrad 2 Schutzart IP20 (Berührschutz nach NEMA 250 Typ 1) Schutzisolierung Isolierung zwischen ankommenden Bus und ...
  • Page 13: Daten Der Anschlussklemmen

    Technische Daten Daten der Anschlussklemmen Daten der Anschlussklemmen Klemme Bezeichnung Funktion / Pegel X3.1/ Externe Spannungsversorgung des Funktionsmoduls U = 24 V DC (21.6 V − 0% ... 26.4 V + 0 %) Stromaufnahme an 24 V DC: I = 90 mA Beim Durchschleifen der Versorgungsspannung zu anderen Busteilnehmern über die Klemme 59 darf der fließende Strom max.
  • Page 14: Abmessungen

    Technische Daten Abmessungen Abmessungen E82ZAFI014B alle Maße in mm EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 15: Mechanische Installation

    Mechanische Installation Mechanische Installation Folgen Sie zur mechanischen Installation des Funktionsmoduls den Hinweisen in der Mon- tageanleitung des Grundgerätes. Die Montageanleitung des Grundgerätes ... ƒ ist Teil des Lieferumfangs und liegt jedem Gerät bei. ƒ gibt Hinweise, um Beschädigungen durch unsachgemäße Behandlung zu vermeiden. ƒ...
  • Page 16: Elektrische Installation

    Elektrische Installation Elektrische Installation Stop! Um Steckerleisten und Kontakte nicht zu beschädigen: Steckerleisten nur aufstecken / abziehen wenn der Antriebsregler vom ƒ Netz getrennt ist. Steckerleisten erst verdrahten, dann aufstecken. ƒ Nicht belegte Steckerleisten ebenfalls aufstecken. ƒ Gebrauch der Steckerleiste mit Federkraftanschluss E82ZAFX013 EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 17: Emv−Gerechte Verdrahtung

    Elektrische Installation EMV−gerechte Verdrahtung EMV−gerechte Verdrahtung Für eine EMV−gerechte Verdrahtung beachten Sie folgende Punkte: Hinweis! Steuer−/Datenleitungen getrennt von Motorleitungen verlegen. ƒ Legen Sie die Schirme der Steuer−/Datenleitungen bei digitalen Signalen ƒ beidseitig auf. Zur Vermeidung von Potenzialdifferenzen zwischen den ƒ Kommunikationsteilnehmern eine Ausgleichsleitung mit einem Querschnitt von mindestens 16 mm einsetzen (Bezug: PE).
  • Page 18: Verdrahtung Mit Einem Leitrechner

    Elektrische Installation Verdrahtung mit einem Leitrechner Verdrahtung mit einem Leitrechner E82ZAFICxxx E82ZAFICxxx E82ZAFICxxx 400 m 400 m E82ZAFI008 Element Beschreibung Leitrechner z. B. PC oder SPS mit INTERBUS Master−Anschaltbaugruppe Buskabel Verbindet die INTERBUS Master−Anschaltbaugruppe mit den Funkti- onsmodulen. INTERBUS−Slave Einsetzbares Grundgerät (^ 8) mit Funktionsmodul. DIP−Schalter S1 einstellen ( ^ 30): –...
  • Page 19 Elektrische Installation Verdrahtung mit einem Leitrechner Spezifikation des Übertragungskabels Allgemeine Eigenschaften Kabeltyp Meterware, (z. B. PHOENIX CONTACT: IBS RBC Meter−T, Best.−Nr. 28 06 28 6) Leiteranzahl 3 × 2, paarig verseilt, mit gemeinsamer Abschirmung Leiterquerschnitt > 0.2 mm DC−Leitungswiderstand < 96 W ±...
  • Page 20: Spannungsversorgung

    Elektrische Installation Spannungsversorgung Spannungsversorgung Interne DC−Spannungsversorgung Die interne Spannung ... ƒ dient der Versorgung der Reglersperre (CINH). ƒ steht an Klemme X3.3/20 zur Verfügung. Externe Spannungsversorgung Hinweis! Verwenden Sie bei externer Spannungsversorgung und bei größeren Entfernungen zwischen den Schaltschränken in jedem Schaltschrank immer ein separates und nach EN 61800−5−1 sicher getrenntes Netzteil (SELV/PELV).
  • Page 21 Elektrische Installation Spannungsversorgung Versorgung der Reglersperre (CINH) Versorgung über die interne Versorgung über die externe Spannungsquelle Spannungsquelle (X3.3/20) GND1 GND1 GND1 GND1 GND2 GND2 X3.2 X3.1 X3.2 X3.1 GND3 GND1 GND3 GND1 +20V +20V X3.3 K + 28 20 A B C D E F G H J X3.3 K + 28 20 A B C D E F G H J...
  • Page 22: Belegung Der Anschlussklemmen

    Elektrische Installation Belegung der Anschlussklemmen Belegung der Anschlussklemmen Klemme Bezeichnung Funktion / Pegel X3.1/ Externe Spannungsversorgung des Funktionsmoduls U = 24 V DC (21.6 V − 0% ... 26.4 V + 0 %) Stromaufnahme an 24 V DC: I = 90 mA Beim Durchschleifen der Versorgungsspannung zu anderen Busteilnehmern über die Klemme 59 darf der fließende Strom max.
  • Page 23: Leitungsquerschnitte Und Schraubenanzugsmomente

    Elektrische Installation Leitungsquerschnitte und Schraubenanzugsmomente Leitungsquerschnitte und Schraubenanzugsmomente Bereich Werte Elektrischer Anschluss 2−polige Steckerleiste mit Federkraftanschluss Anschlussmöglichkeiten starr: 1.5 mm (AWG 16) flexibel: ohne Aderendhülse 1.5 mm (AWG 16) mit Aderendhülse, ohne Kunststoffhülse 1.5 mm (AWG 16) mit Aderendhülse, mit Kunststoffhülse 1.5 mm (AWG 16) Abisolierlänge...
  • Page 24: Inbetriebnahme

    Inbetriebnahme Vor dem ersten Einschalten Inbetriebnahme Vor dem ersten Einschalten Stop! Bevor Sie das Grundgerät mit dem Funktionsmodul erstmalig einschalten, überprüfen Sie ... die gesamte Verdrahtung auf Vollständigkeit, Kurzschluss und Erdschluss. ƒ die Einstellung des DIP−Schalters S1 (^ 30): ƒ –...
  • Page 25: Inbetriebnahmeschritte

    Inbetriebnahme Inbetriebnahmeschritte Inbetriebnahmeschritte Hinweis! Halten Sie unbedingt die Einstellreihenfolge ein. Die schrittweise Inbetriebnahme des Funktionsmoduls mit der DRIVECOM−Gerätesteue- rung ist nachfolgend beschrieben. Schritt Vorgehensweise Ausführliche Information ^ 27 Leitrechner (Master) für die Kommunikation mit dem Funktionsmo- dul konfigurieren. Grundgerät über Klemme 28 (CINH) sperren. Dokumentation des Grundgerä- Klemme 28 auf LOW−Pegel legen.
  • Page 26 – Steuerworte und Statusworte sind dabei bereits verknüpft. Kommunikati- Über C1511 die Prozess−Ausgangsdatenwörter (PAW) des Masters onshandbuch den Prozess−Eingansdatenwörtern des Grundgerätes zuordnen. INTERBUS Lenze−Einstellung: PAW1: DRIVECOM−Steuerwort (DRIVECOM CTRL) PAW2: Sollwert1 (NSET1−N1) PAW3: Sollwert2 (NSET1−N2) PAW4: Zusatzsollwert (PCTRL1−NADD) Kommunikati- Über C1510 die Prozess−Ausgangsdatenwörter des Grundgerätes den onshandbuch Prozess−Eingansdatenwörtern (PEW) des Masters zuordnen.
  • Page 27: Leitsystem (Master) Konfigurieren

    Zur Kommunikation mit dem Funktionsmodul muss zunächst der Leitrechner (Master) kon- figuriert werden. Einstellungen am Master Zur Projektierung des INTERBUS muss in der Projektierungssoftware des Masters die Gerä- tebeschreibungsdatei (EDS−Datei) der Kommunikationsbaugruppe eingelesen werden. Die EDS−Datei können Sie im Download−Bereich unter http://www.Lenze.com herunterla- den. EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 28: Nutzdatenlänge Festlegen

    ƒ Sobald einer der DIP−Schalter S2 ... S4 = OFF eingestellt ist, werden beim Einschalten die Konfigurationen aus allen Schalterstellungen aktiv. ƒ Bei ungültiger Schalterstellung wird die Lenze−Einstellung aktiv: – DIP−Schalter S2 ... S4 = OFF (2 PZD−Wörter + 1 PCP−Wort) ƒ...
  • Page 29 ƒ DIP−Schalter S2 ... S4 = ON ƒ Die Anzahl der Datenwörter (PZD + PCP) über C1515 einstellen. Code Name Index C1515 Prozess−/Parameterdaten−Spezifikation 0x5A14 (23060) Subcode Lenze Werte Zugriff Datentyp − 0, 1, 4, 5 FIX32 Werte Beschreibung 0, 1, 4, 5 Die Konfiguration aus den DIP−Schalterstellungen wird entsprechend...
  • Page 30: Einstellung Für Letzten Busteilnehmer

    2 3 4 E82ZAFI009 Hinweis! Nur beim physikalisch letzten Busteilnehmer muss der DIP−Schalter 1 ƒ auf OFF eingestellt sein. Lenze−Einstellung: alle Schalter OFF ƒ Stellung Hinweise Grundgerät mit Funktionsmodul ist letzter Bus−Teilnehmer Grundgerät mit Funktionsmodul ist nicht letzter Bus−Teilnehmer. EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 31: Netzspannung Zuschalten

    Nach einer Störung (z. B. kurzzeitiger Netzausfall) ist der Wiederanlauf eines Antriebs in manchen Fällen unerwünscht oder sogar unzulässig. In C0142 lässt sich das Wiederanlaufverhalten des Antriebsreglers einstellen: C0142 = 0 (Lenze−Einstellung) ƒ – Der Antriebsregler bleibt gesperrt (auch wenn die Störung nicht mehr aktiv ist).
  • Page 32: Diagnose

    Diagnose LED−Statusanzeigen Diagnose LED−Statusanzeigen E82ZAFI014B Pos. Farbe Zustand Beschreibung gelb Keine Kommunikation mit dem INTERBUS−Master vorhanden. blinkt Die Kommunikation über das Funktionsmodul zum INTERBUS− Master ist aufgebaut. Interner Fehler des Funktionsmoduls grün Das Funktionsmodul wird nicht mit Spannung versorgt. Das Grundgerät und/oder die externe Spannungsversorgung ist ausgeschaltet.
  • Page 33 Diagnose LED−Statusanzeigen EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 34 Legend for fold−out page Pos. Description Detailed information ^ 62 LED (yellow): Status of the INTERBUS communication LED (green): Connection status to the controller ^ 60 DIP switch S1 Setting for the last node = OFF Setting for all other nodes = ON DIP switches S2 ...
  • Page 35 Contents About this documentation ..........Safety instructions .
  • Page 36: About This Documentation

    This documentation includes ... ƒ Safety instructions which you must observe in any case; ƒ Data about the versions of Lenze standard devices to be used; ƒ Information about the mechanical and electrical installation of the function module; ƒ Information about the commissioning of the function module;...
  • Page 37: Safety Instructions

    Safety instructions Safety instructions Danger! Inappropriate handling of the function module and the standard device can cause serious injuries to persons and damage to material assets. Observe the safety instructions and residual hazards included in the documentation of the standard device. Stop! Electrostatic discharge Electronic components within the function module can be damaged or...
  • Page 38: Product Description

    The function module connects the standard device to the INTERBUS communication system. Application as directed The function module ... ƒ is an accessory module for use in conjunction with the following Lenze standard devices: Product series Device name From hardware version...
  • Page 39: Scope Of Supply

    Product description Scope of supply Scope of supply E82ZAFI014B, AFX006/007/011/012 Pos. Scope of supply E82ZAFIC010 function module Mounting instructions 2 plug connectors with spring connection, 3−pole Plug connector with spring connection, 13−pole Mounting clip (for use see Operating Instructions/mounting instructions for 8200 vector) EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 40: Identification

    Product description Identification Identification ‚ƒ  ‚ƒ A22 APPLICATION APPLICATION 010 / 3A22 010 / 3A22 Type Id.-No. Prod.-No. Ser.-No. E82AF000P0B201XX E82ZAFX005  ‚ ƒ E82ZAF Product series INTERBUS Version Variant: PT (plug terminal) with spring connection Hardware version Software version EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 41: Technical Data

    Technical data General data Technical data General data Area Values Order designation E82ZAFIC010 Communication medium RS485 Network topology Ring (go and return line in the same cable) Number of bus nodes Dependent on INTERBUS master (e.g. Phoenix Contact G4 master). For the following data, which depend on whether PCP communication is used or not, always the smaller value applies: with PCP communication: max.
  • Page 42: Operating Conditions

    1K3 (−25 to +60 °C) Transport IEC/EN 60721−3−2 2K3 (−25 to +70 °C) Operation Corresponding to the data of the Lenze standard device used (see documentation of the standard device). Pollution EN 61800−5−1 Degree of pollution 2 Degree of protection...
  • Page 43: Connection Terminals

    Technical data Connection terminals Connection terminals Terminal Designation Function / level X3.1/ External voltage supply of the function module U = 24 V DC (21.6 V − 0% ... 26.4 V + 0 %) Current consumption for 24 V DC: I = 90 mA If the supply voltage is looped through to other bus nodes via terminal 59, the current flowing must not exceed 3 A.
  • Page 44: Dimensions

    Technical data Dimensions Dimensions E82ZAFI014B All dimensions in mm EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 45: Mechanical Installation

    Mechanical installation Mechanical installation Follow the notes given in the Mounting Instructions for the standard device for the mechanical installation of the function module. The Mounting Instructions for the standard device ... ƒ are part of the scope of supply and are enclosed with each device. ƒ...
  • Page 46: Electrical Installation

    Electrical installation Electrical installation Stop! Observe the following to prevent any damage to plug connectors and contacts: Only pug in / unplug the plug connectors when the controller is ƒ disconnected from the mains. Wire the plug connectors before plugging them in. ƒ...
  • Page 47: Wiring According To Emc

    Electrical installation Wiring according to EMC Wiring according to EMC For wiring according to EMC requirements observe the following points: Note! Separate control cables/data lines from motor cables. ƒ Connect the shields of control cables/data lines at both ends in the case of ƒ...
  • Page 48: Wiring To A Host

    Electrical installation Wiring to a host Wiring to a host E82ZAFICxxx E82ZAFICxxx E82ZAFICxxx 400 m 400 m E82ZAFI008 Element Description Host E.g. PC or PLC with INTERBUS master interface module Bus cable Connects the INTERBUS master interface module to the function modules.
  • Page 49 Electrical installation Wiring to a host Specification of the transmission cable General characteristics Cable type Sold by the meter, (e.g. PHOENIX CONTACT: IBS RBC Meter−T, Order No. 28 06 28 6) Number of conductors 3 × 2, twisted pairs, with shared shield Conductor cross−section >...
  • Page 50: Voltage Supply

    Electrical installation Voltage supply Voltage supply Internal DC voltage supply The internal voltage ... ƒ supplies the controller inhibit (CINH). ƒ is available at terminal X3.3/20. External voltage supply Note! In the case of an external voltage supply and for greater distances between the control cabinets, always use a separate power supply unit (SELV/PELV) that is safely separated in accordance with EN 61800−5−1 in each control cabinet.
  • Page 51 Electrical installation Voltage supply Supply of controller inhibit (CINH) Supply via internal voltage source (X3.3/20) Supply via external voltage source GND1 GND1 GND1 GND1 GND2 GND2 X3.1 X3.2 X3.1 X3.2 GND3 GND1 GND3 GND1 +20V +20V X3.3 K + 28 20 A B C D E F G H J X3.3 K + 28 20...
  • Page 52: Assignment Of The Terminals

    Electrical installation Assignment of the terminals Assignment of the terminals Terminal Designation Function / level X3.1/ External voltage supply of the function module U = 24 V DC (21.6 V − 0% ... 26.4 V + 0 %) Current consumption for 24 V DC: I = 90 mA If the supply voltage is looped through to other bus nodes via terminal 59, the current flowing must not exceed 3 A.
  • Page 53: Cable Cross−Sections And Screw−Tightening Torques

    Electrical installation Cable cross−sections and screw−tightening torques Cable cross−sections and screw−tightening torques Field Values Electrical connection 2−pin plug connector with spring connection Possible connections rigid: 1.5 mm (AWG 16) flexible: without wire end ferrule 1.5 mm (AWG 16) with wire end ferrule, without plastic sleeve 1.5 mm (AWG 16) with wire end ferrule, with plastic sleeve...
  • Page 54: Commissioning

    Commissioning Before switching on Commissioning Before switching on Stop! Before you switch on the standard device and the plugged−in function module for the first time, check ... the entire wiring for completeness, short circuit and earth fault. ƒ the setting of the DIP switch S1 (^ 60): ƒ...
  • Page 55: Commissioning Steps

    Commissioning Commissioning steps Commissioning steps Note! Do not change the setting sequence. Step−by−step commissioning of the function module with the DRIVECOM device control is described below. Step Procedure Detailed information ^ 57 Configure the host (master) for communication via the function module.
  • Page 56 Use C1511 to assign the process output data words (POW) of the communication master to the process input data words of the standard device. manual Lenze setting: POW1: DRIVECOM control word (DRIVECOM CTRL) POW2: Setpoint1 (NSET1−N1) POW3: Setpoint2 (NSET1−N2) POW4: Additional setpoint (PCTRL1−NADD)
  • Page 57: Configuring The Host System (Master)

    Master settings The configuration of the INTERBUS requires the device description file (EDS file) for the communication module to be imported to the master configuration software. The EDS file can be downloaded in the download area on http://www.Lenze.com. EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 58: Defining The User Data Length

    ƒ If one of the DIP switches S2 ... S4 is set to OFF, the configurations resulting from all switch positions are active at switch−on. ƒ If the switch positions are invalid, the Lenze setting is activated: – DIP switches S2 ... S4 = OFF (2 PCD words + 1 PCP word) ƒ...
  • Page 59 ƒ DIP switches S2 ... S4 = ON ƒ Set the number of data words (PCD + PCP) via C1515. Code Name Index C1515 Process/parameter data specification 0x5A14 (23060) Subcode Lenze Values Access Data type − 0, 1, 4, 5 FIX32 Values Description...
  • Page 60: Setting For Last Bus Node

    2 3 4 E82ZAFI009 Note! DIP switch 1 must only be set to OFF for the last physical node. ƒ Lenze setting: all switches OFF ƒ Position Notes Standard device with function module is the last bus node Standard device with function module is not the last bus node.
  • Page 61: Connecting The Mains Voltage

    − in some cases − even not allowed. The restart behaviour of the controller can be set in C0142: C0142 = 0 (Lenze setting) ƒ – The controller remains inhibited (even if the fault is no longer active).
  • Page 62: Diagnostics

    Diagnostics LED status displays Diagnostics LED status displays E82ZAFI014B Pos. Colour Condition Description Yellow No communication with the INTERBUS master. Blinking Communication to the INTERBUS master via the function module is established. Internal error in the function module Green The function module is not supplied with voltage. The standard device and/or the external voltage supply is/are switched off.
  • Page 63 Diagnostics LED status displays EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 64 Légende de l’illustration de la page dépliante Pos. Description Informations détaillées ^ 93 LED (jaune) : état de la communication INTERBUS LED (verte) : état de la liaison avec le variateur ^ 91 Interrupteur DIP S1 Réglage du dernier participant au bus = OFF Réglage de tous les autres participants au bus = ON Interrupteurs DIP S2 ...
  • Page 65 Sommaire Présentation du document ..........Consignes de sécurité...
  • Page 66: Présentation Du Document

    La présente documentation contient ... ƒ des consignes de sécurité à respecter impérativement ; ƒ les valeurs indiquées concernant les versions des appareils de base Lenze à utiliser ; ƒ des informations sur l’installation mécanique et électrique du module de fonction ;...
  • Page 67: Consignes De Sécurité

    Consignes de sécurité Consignes de sécurité Danger ! Toute utilisation contre−indiquée du module de fonction et de l’appareil de base peut entraîner des blessures graves et des dommages matériels. Tenir compte des consignes de sécurité et des dangers résiduels énoncés dans la documentation de l’appareil de base.
  • Page 68: Description Du Produit

    Conseil ! Pour de plus amples renseignements sur ce module de fonction, se reporter au manuel de communication correspondant. Celui−ci est disponible au format PDF et peut être téléchargé à l’adresse suivante (zone de téléchargement) : http://www.Lenze.com EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 69: Equipement Livré

    Description du produit Equipement livré Equipement livré E82ZAFI014B, AFX006/007/011/012 Pos. Contenu de l’emballage Module de fonction E82ZAFIC010 Instructions de montage 2 borniers à lame ressort, à 3 bornes Bornier à lame ressort, à 13 bornes Etrier de fixation (pour l’utilisation, voir les instructions de mise en service/instructions de montage du 8200 vector) EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 70: Identification

    Description du produit Identification Identification ‚ƒ  ‚ƒ A22 APPLICATION APPLICATION 010 / 3A22 010 / 3A22 Type Id.-No. Prod.-No. Ser.-No. E82AF000P0B201XX E82ZAFX005  ‚ ƒ E82ZAF Série d’appareils INTERBUS Génération d’appareils Variante : PT (Plug Terminal) avec raccordement par lames de ressorts Version matérielle Version logicielle EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 71: Spécifications Techniques

    Spécifications techniques Caractéristiques générales Spécifications techniques Caractéristiques générales Domaine Valeurs Référence de commande E82ZAFIC010 Support de communication RS485 Topologie du réseau Anneau (aller et retour dans le même câble) Nombre de participants En fonction du maître INTERBUS (par exemple, maître Phoenix Contact G4).
  • Page 72: Conditions D'utilisation

    CEI/EN 60721−3−1 1K3 (−25 ... +60 °C) Transport CEI/EN 60721−3−2 2K3 (−25 ... +70 °C) Fonctionnement Conformément aux données de l’appareil de base Lenze utilisé (voir la documentation de l’appareil de base). Pollution ambiante EN 61800−5−1 Degré de pollution 2 admissible...
  • Page 73: Spécifications Des Bornes De Raccordement

    Spécifications techniques Spécifications des bornes de raccordement Spécifications des bornes de raccordement Bornier Désignation Fonction / niveau X3.1/ Alimentation externe du module de fonction U = 24 V CC (21.6 V − 0% ... 26.4 V + 0 %) Courant absorbé sur 24 V CC : I = 90 mA Le courant traversant la borne 59 lors du bouclage de la tension d’alimentation avec d’autres participants au bus ne doit pas dépasser 3 A .
  • Page 74: Encombrements

    Spécifications techniques Encombrements Encombrements E82ZAFI014B Toutes les cotes en mm EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 75: Installation Mécanique

    Installation mécanique Installation mécanique Pour l’installation mécanique du module de fonction, suivre les consignes fournies dans les instructions de montage de l’appareil de base. Les instructions de montage de l’appareil de base ... ƒ font partie de la livraison standard et sont comprises dans l’emballage. ƒ...
  • Page 76: Installation Électrique

    Installation électrique Installation électrique Stop ! Pour éviter d’endommager les borniers et les contacts : Enficher et retirer les borniers uniquement lorsque le variateur est coupé ƒ du réseau. Procéder au câblage des borniers avant de les enficher. ƒ Enficher également des borniers non affectés. ƒ...
  • Page 77: Câblage Conforme Cem

    Installation électrique Câblage conforme CEM Câblage conforme CEM Pour s’assurer que le câblage est conforme aux exigences à respecter en matière de CEM, vérifier les points suivants : Remarque importante ! Séparer physiquement les câbles de commande/de données des câbles ƒ...
  • Page 78: Raccordement À Un Maître

    Installation électrique Raccordement à un maître Raccordement à un maître E82ZAFICxxx E82ZAFICxxx E82ZAFICxxx 400 m 400 m E82ZAFI008 N° Elément Description Maître Exemple : PC ou API avec interface maître INTERBUS Câble bus Relie l’interface maître INTERBUS aux modules de fonction Esclave INTERBUS Appareil de base utilisable (^ 68) avec module de fonction Réglage de l’interrupteur DIP S1 ( ^ 91):...
  • Page 79 Installation électrique Raccordement à un maître Spécifications pour câble de transmission Caractéristiques générales Type de câble Au mètre, (ex. : PHOENIX CONTACT : IBS RBC Meter−T, réf. de commande 28 06 28 6) Nombre de conducteurs 3 × 2, torsadés par paire, avec blindage Section de câble >...
  • Page 80: Alimentation

    Installation électrique Alimentation Alimentation Alimentation CC interne La tension interne... ƒ sert à l’alimentation de la borne de blocage variateur (CINH). ƒ est mise à disposition sur le bornier X3.3/20. Alimentation externe Remarque importante ! En cas d’alimentation externe et d’écarts importants entre les armoires électriques, toujours utiliser un bloc d’alimentation avec coupure de sécurité...
  • Page 81 Installation électrique Alimentation Alimentation du blocage variateur (CINH) Alimentation via la source de tension Alimentation via la source de tension externe interne (X3.3/20) GND1 GND1 GND1 GND1 GND2 GND2 X3.2 X3.1 X3.2 X3.1 GND3 GND1 GND3 GND1 +20V +20V X3.3 K + 28 20 A B C D E F G H J X3.3...
  • Page 82: Affectation Des Bornes De Raccordement

    Installation électrique Affectation des bornes de raccordement Affectation des bornes de raccordement Bornier Désignation Fonction / niveau X3.1/ Alimentation externe du module de fonction U = 24 V CC (21.6 V − 0% ... 26.4 V + 0 %) Courant absorbé sur 24 V CC : I = 90 mA Le courant traversant la borne 59 lors du bouclage de la tension d’alimentation avec d’autres participants au bus ne doit pas dépasser 3 A .
  • Page 83: Sections Des Câbles Et Couples De Serrage Des Vis

    Installation électrique Sections des câbles et couples de serrage des vis Domaine Valeurs Raccordement électrique Bornier à lame ressort 2 bornes Possibilités de Rigide : raccordement 1.5 mm (AWG 16) Flexible : sans embout 1.5 mm (AWG 16) avec embout, sans cosse en plastique 1.5 mm (AWG 16) avec embout et cosse en plastique...
  • Page 84: Mise En Service

    Mise en service Avant la première mise sous tension Mise en service Avant la première mise sous tension Stop ! Avant la première mise sous tension de l’appareil de base avec le module de fonction, vérifiez les points suivants : Le câblage est−il complet ? S’assurer de l’absence de court−circuit et de ƒ...
  • Page 85: Etapes De Mise En Service

    Mise en service Etapes de mise en service Etapes de mise en service Remarque importante ! Respecter impérativement l’ordre des opérations de réglage. Les étapes de la mise en service du module de fonction à l’aide du contrôle DRIVECOM sont décrites ci−dessous.
  • Page 86 Affecter les mots de données process de sortie (PAW) du maître aux communication mots de données process d’entrée de l’appareil de base via C1511. INTERBUS Réglage Lenze : PAW1 : Mot de commande DRIVECOM (DRIVECOM−CTRL) PAW2 : Consigne 1 (NSET1−N1) PAW3 : Consigne 2 (NSET1−N2) PAW4 : Consigne supplémentaire (PCTRL1−NADD)
  • Page 87 Mise en service Etapes de mise en service Etape Action Informations détaillées Manuel de Passer à l’état PRET A FONCTIONNER : communication Le maître transmet le mot de commande DRIVECOM : INTERBUS 0000 0000 0111 1110 (007E L’appareil de base est à l’état PRET A FONCTIONNER. Le maître réceptionne le mot d’état DRIVECOM : xxxx xxxx x01x 0001 bin.
  • Page 88: Configuration Du Maître

    Pour pouvoir élaborer le projet INTERBUS, il faut charger le fichier descriptif (fichier EDS) du module de communication vers le logiciel de conception du maître. Vous trouverez le fichier descriptif dans la zone de téléchargements, à l’adresse suivante : http://www.Lenze.com. EDK82ZAFIC−010 DE/EN/FR 6.0...
  • Page 89: Réglage De La Longeur Des Données Utiles

    ƒ Dès lors que l’un des interrupteurs DIP S2 ... S4 = OFF, à la mise sous tension, les configurations découlant de toutes les positions des interrupteurs sont activées. ƒ Si la position d’un interrupteur est incorrecte, le réglage Lenze est activé : – Interrupteurs DIP S2 ... S4 = OFF (2 mots PZD + 1 mot PCP) ƒ...
  • Page 90 ƒ Interrupteurs DIP S2 ... S4 = ON ƒ Régler le nombre de mot de données (PZD + PCP) en C1515. Code Désignation Index C1515 Spécifications données process/param. 0x5A14 (23060) Sous−code Lenze Valeurs Accès Type de données − 0, 1, 4, 5 FIX32 Valeurs...
  • Page 91: Réglage Pour Le Dernier Participant Au Bus

    Remarque importante ! L’interrupteur 1 doit être réglé sur OFF uniquement pour le dernier ƒ participant au bus (physiquement). Réglage Lenze de tous les interrupteurs : OFF ƒ Position Remarque L’appareil de base avec le module de fonction est le dernier participant au bus.
  • Page 92: Mise Sous Tension

    Le code C0142 permet de configurer les caractéristiques de redémarrage du variateur de vitesse : C0142 = 0 (réglage Lenze) ƒ – Le variateur de vitesse reste bloqué (même après élimination du problème).
  • Page 93: Diagnostic

    Diagnostic Affichage d’état par LED Diagnostic Affichage d’état par LED E82ZAFI014B Pos. Couleur Etat Description Jaune Absence de communication avec le maître INTERBUS. Clignote La communication avec le maître INTERBUS via le module de fonction est établie. Défaut interne du module de fonction Vert Le module de fonction n’est pas sous tension.
  • Page 94 © 10/2013 Lenze Drives GmbH Service Lenze Service GmbH Postfach 10 13 52 Breslauer Straße 3 D−31763 Hameln D−32699 Extertal Germany Germany +49 (0)51 54 / 82−0 00 80 00 / 24 4 68 77 (24 h helpline) Ê Ê...

Ce manuel est également adapté pour:

E82zafic010

Table des Matières