Commissioning

Defining the user data length

Defining the user data length
The number of process data words (PCD) and parameter data words (PCP) can be set via
code C1515 or via the DIP switches S2 ... S4.
)
Note!
Sum of all data words (PZD + PCP): max. 4 words
ƒ
Switch off the voltage supply of the function module and the controller
ƒ
and then on again to activate the changed settings.
Settings via DIP switches S2 ... S4
ON
1
2 3 4
ƒ If one of the DIP switches S2 ... S4 is set to OFF, the configurations resulting from all
switch positions are active at switch−on.
ƒ If the switch positions are invalid, the Lenze setting is activated:
– DIP switches S2 ... S4 = OFF (2 PCD words + 1 PCP word)
ƒ Code C1525 displays the current settings of the DIP switches S2 ... S4.
DIP switch
S2
S3
S4
OFF
OFF
OFF
ON
OFF
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
58
Value
Number of process
data words (PCD)
0
1
4
5
Code C1515 active.
l
ON
OFF
Number of parameter
data words (PCP)
2
3
2
4
E82ZAFI009
ID code
1
227
1
227
0
3
0
3
EDK82ZAFIC−010 DE/EN/FR 6.0