General Data And Operating Conditions; Technical Data - Lenze E82ZZ B200 Serie Instructions De Montage

Filtre antiparasite
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

3

Technical data

General data and operating conditions

Standards
Approval
Mains data
Mains types
With grounded neutral (TT /TN systems)
IT systems
Protection
Type of protection
Insulation resistance
Leakage current
E82ZZ...B200
E82ZZ...B210
E82ZZ...B220
Ambient conditions
Temperature
Storage
Transport
Operation
Site altitude
Pollution
Vibration resistance
Mounting conditions
Mounting location
Position
Mounting position
EDK82ZZ113 DE/EN/FR 2.1
General data and operating conditions
UL
230 V
400 V
EN 60529
NEMA 250
EN 61800-5-1
EN 61800-5-1
EN 61800-5-1
EN 50178, IEC 61800-5-1,
Germanischer Lloyd,
general conditions
In the control cabinet
Standard: between mounting plate and basic device
Variant: to the left of the basic device
Vertical, connections on top
UL 508C, Component Power Conversion Equipment -
Accessories (file no. E132659) for the US and Canada
Operation permitted without restrictions
Observe instructions for special measures in the
documentation for the basic device!
Max. mains voltage 400 V!
Observe instructions for special measures in the
documentation for the basic device!
IP 20
Protection against contact to
type 1
Overvoltage category III
> 2000 m: Overvoltage category II
> 3.5 mA
< 3.5 mA
-25 ... +60 °C
-25 ... +70 °C
-10 ... +55 °C
Current derating from +40 to +55 °C: 2.5 %/°C
0 ... 4000 m amsl
1000 ... 4000 m amsl: Current derating by 5 %/1000 m
Pollution degree 2
Acceleration-resistant up to 0.7 g
Technical data
Not in the wire range of
the terminals
Observe regulations and
safety instructions!
3
21

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

E82zz b210 serieE82zz b220 serie

Table des Matières