OUTPUT SPECIFICATIONS
Output Voltage Range:
Output Current Range:
Output Voltage Setting:
Output Current Setting:
Output Mode:
Output Switch:
Output Terminals:
Sensing:
Output Protection:
OVP Setting:
OVP Range:
OVP Delay:
Load Regulation:
Line Regulation:
Ripple & Noise:
(20MHz bandwidth)
HF Common Mode
Noise:
Transient Response:
Temperature Coefficient:
Protection Functions:
Status Indication:
METER SPECIFICATIONS
Meter Types:
Meter Resolution:
Meter Accuracy:
2
0V to 35.3V (35V/10A); 0V to 18.15V (18V/20A).
0.01A to 10.2A (35V/10A); 0.01A to 20.2A (18V/20A).
Direct keyboard entry or quasi-analog rotary control; setting resolution
10mV.
Direct keyboard entry or quasi-analog rotary control; setting resolution
10mA.
Constant voltage or constant current with automatic crossover.
Electronic. Preset voltage and current displayed when off.
Front panel: Universal 4mm safety binding posts on 19mm (0·75") spacing
Rear panel: Terminal block screw terminals.
Remote via rear panel terminal block screw terminals or direct via shorting
strip (supplied).
Forward protection by Over-Voltage-Protection (OVP) trip.
Output will withstand an applied forward voltage of up to 50V (35V/10A) or
35V (18V/20A).
Reverse protection by diode clamp for reverse currents up to 3A.
Direct keyboard entry.
1V to 40V (35V/10A); 1V to 25V (18V/20A).
<200µs
For any load change, measured at the O/P terminals, using remote sense:
Constant voltage: <0.01% ± 5mV
Constant current: < 0.01% ±0.5mA
Change in output for a 10% line change:
Constant voltage: <0.01% ± 5mV
Constant current: < 0.01% ± 250uA
Typically <1mV rms; <3mVrms max in CV mode.
Typically <3mA rms; <5mArms max in CI
Typically <3mV rms, <15mV peak.
100µs to within 50mV of setting for a 5% to 95% load change.
Typically <100 ppm/°C.
Overvoltage trip; regulator overtemperature; sense miswiring.
LED indicators for Output ON, constant voltage mode, constant current
mode, current meter damping, remote operation, and LAN status; trip &
error messages on display.
Dual 4 digit meters with 12·5mm (0.5") LEDs. Reading rate 4Hz.
10mV, 10mA
Voltage 0.2% of reading ± 1 digit, current 0.5% of reading ± 1 digit.

Specification

mode.