General specifications apply for the temperature range 5°C to 40°C. Accuracy specifications
apply for the temperature range 18°C to 28°C after 1 hour warm-up with no load and calibration at
23°C. Typical specifications are determined by design and are not guaranteed.
OUTPUT SPECIFICATIONS (Each Output)
Voltage Range:
Current Range:
Power Range:
Voltage Setting:
Current Setting:
Operating Mode:
Output Switch:
Output Terminals:
Sensing:
Ripple & Noise
(20MHz bandwidth):
Load Regulation:
Line Regulation:
Transient Response:
Output Protection:
Over-voltage Protection
(OVP):
Over-current Protection
(OCP):
Over-temperature
Protection:
Temperature Coefficient:
Two ranges: 0V to 60V or 0V to 80V
0.01A to 50A
Up to 600W
Resolution: 1mV (60V Range),
2mV (80V Range)
Accuracy: 0.1% of setting ± 2mV,
(± 4mV on 80V range)
Resolution 10mA
Accuracy: 0.3% of setting ± 20mA
Constant voltage or constant current
with automatic cross-over provided
that the power demanded stays within
the power envelope, see graph.
Outside of this envelope the output
becomes unregulated. CV, CC or
UNREG mode indication in display.
Independent electronic switching, with ON indication. In addition, BOTH ON
and BOTH OFF keys permit both outputs to be switched on/off
synchronously (±10µs). Preset voltage and current displayed when off.
Rear panel safety terminals accepting 6mm wire diameter, 6mm plugs or
8mm spades at 50 Amps max, or 4mm plugs at 30 Amps max.
Switchable between local and remote. Screwless remote sense terminals on
rear panel. Sense miswiring trip and indication.
Typically <3mVrms, <20mV pk-pk at maximum load, CV mode
Change in output for any load change within PowerFlex envelope, using
remote sense:
Constant voltage: <0.01% ± 5mV
Change in output for a 10% line change:
Constant voltage: <0.01% ± 5mV
<2ms to within 100mV of set level for a 5% to 95% load change.
Output will withstand an applied forward voltage of up to 90V.
Reverse protection by diode clamp for reverse currents up to 3A.
Range 2V to 90V. Resolution 0.1V; accuracy: 0.2% ± 0.2V.
Response time typically 100µs.
Range 2A to 55A. Resolution 0.1A; accuracy: 0.5% ± 0.2A.
Response time typically 100ms.
The output will be tripped off if a fault causes the internal temperature to rise
excessively.
Typically <100ppm/°C