The EX355R is an exceptionally compact and lightweight single output laboratory dc power
supply providing 0 to 35V at 0 to 5A.
The EX355R uses mixed-mode regulation technology which combines switch-mode pre-
regulation with linear post-regulation. Special techniques are used to maintain very high efficiency
whilst achieving noise levels that are close to that of a pure linear regulator.
Excellent line and load regulation are matched by low noise and good transient response. High
power efficiency ensures that the unit remains cool without any fan noise. High resolution
controls allow accurate setting of voltage and current levels. Remote sense terminals are
provided so that good regulation can be maintained across remote loads at high current.
The output operates in constant voltage or constant current mode with automatic cross-over and
mode indication. There is a DC output on-off switch.
The EXR series incorporates separate digital voltage and current meters on each output. The
meters use bright 14mm (0.56") LED displays and have an update rate of 4 per second providing
near instantaneous response. Simultaneous metering of voltage and current provides accurate
information "at a glance" and avoids any possibility of misinterpretation. When the output switch
is set to "off", the current limit setting is displayed enabling conditions to be set before the load is
connected.
The EXR series has been designed to meet the stringent requirements of the latest relevant IEC
standards for safety and EMC, including harmonics emissions. All outputs are intrinsically short
circuit proof, and are protected against external voltages and reverse currents.
OUTPUT
Voltage Range:
Current Range:
Output Voltage Setting:
Output Current Setting:
Operating Mode:
Output Switch:
Output Terminals:
Sensing:
Output Protection:
Load Regulation:
Line Regulation:
Ripple & Noise
(20MHz bandwidth):
Transient Response:
Temperature Coefficient:
Status Indication:
2
0V to 35V minimum
0A to 5A minimum
By coarse and fine controls.
By single logarithmic control.
Constant voltage or constant current with automatic cross-over.
Electronic. Preset voltage and current displayed when off.
Universal 4mm safety binding posts on 19mm (0.75") pitch.
Switchable between local and remote. Spring-loaded push terminals
for remote connection.
Output will withstand up to 40V forward voltage.
Reverse protection by diode clamp for reverse currents up to 3A.
<0.01% of maximum output for 90% load change, using remote sense.
<0.01% of maximum output for 10% line change.
Typically <2mVrms, <10mV pk-pk, constant voltage mode.
<200µs to within 50mV of set level for a 5% to 95% load change.
Typically <100ppm/°C
Output on lamp. Constant current mode lamp.

Introduction

Specification